| General specifications |
| Switching element function | NO/NC programmable |
| Rated operating distance | 40 mm |
| Installation | non-flush |
| Output polarity | AS-Interface |
| Assured operating distance | 0 ... 32.4 mm |
| Reduction factor rAl | 0.3 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.75 |
| Slave type | A/B slave |
| AS-Interface specification | V3.0 |
| Required master specification | ≥ V2.1 |
| Nominal ratings |
| Operating voltage | 26.5 ... 31.9 V via AS-i bus system |
| Switching frequency | 0 ... 50 Hz |
| Hysteresis | typ. 5 % |
| Reverse polarity protection | reverse polarity protected |
| No-load supply current | ≤ 25 mA |
| Operating voltage display | LED, green |
| Switching state indication | LED, yellow |
| Fault indication | LED, red |
| Functional safety related parameters |
| MTTFd | 1330 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
| Connection type | Connector M12 x 1 , 4-pin |
| Housing material | PA |
| Sensing face | PA |
| Protection degree | IP69K |
| Mass | 210 g |