Datasheet excerpt: Technical data of NBB5-18GM60-A2

General specifications
Switching element functionPNP NO/NC
Rated operating distance5 mm
Installationflush
Output polarity[###] DC
Assured operating distance0 ... 4.05 mm
Reduction factor rAl 0.25
Reduction factor rCu 0.15
Reduction factor r304 0.66
Nominal ratings
Operating voltage10 ... 30 V
Switching frequency0 ... 800 Hz
Hysteresistyp. 5%
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 20 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1140 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross-section0.34 mm2
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter18 mm
Degree of protectionIP67

Documents: NBB5-18GM60-A2

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF191 KB
EinbaubedingungenGERPDF194 KB

CAD+CAE: NBB5-18GM60-A2

CADFile TypeFile Size
3D Modell/3D modelIGS60 KB
3D Modell/3D modelSTP47 KB

Approvals+Certificates: NBB5-18GM60-A2

CertificatesCertificate No.File TypeFile Size
US CA UL General PurposeE87056LINK---
Europe Pepperl+Fuchs 2004/108/EC (EMC) Declaration of ConformityPF 08 CERT 1262PDF357 KB
US CA CSA1007121 (LR96321-2)PDF101 KB

Associated Products: NBB5-18GM60-A2

AccessoriesName
EXG-18Mounting aid
BF 18Mounting flange