Switch Amplifiers





View All Products in Group: Switch Amplifiers


First PagePrevious Page1 - 10 ( of 20 ) Next PageLast Page
Items per Page:
ProductShort Description
Switch Amplifier
KCD2-SR-1.LB
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-1.LB.SP
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-2
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Switch Amplifier
KCD2-SR-2.SP
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals, Up to SIL2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
Conductivity Switch Amplifier
KFA5-ER-1.5
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.6
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control, Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-1.W.LB
1-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA5-ER-2.W.LB
2-channel signal conditioner, 115 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.5
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 30 kΩ, Relay contact output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
Conductivity Switch Amplifier
KFA6-ER-1.6
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control, Input: Conductive, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Output: relay
First PagePrevious Page1 - 10 ( of 20 ) Next PageLast Page
Items per Page: