| Product Description |
| Single head system |
| General specifications |
| Sensing range | 200 ... 4000 mm |
| Adjustment range | 240 ... 4000 mm |
| Unusable area | 0 ... 200 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 85 kHz |
| Response delay | ≤ 180 ms |
| Indicators/operating means |
| LED green | Operating display |
| LED yellow | object in evaluation range |
| LED red | error |
| Electrical specifications |
| Operating voltage | 12 ... 30 V DC , ripple 10 %SS |
| No-load supply current | ≤ 50 mA |
| Interface |
| Interface type | Serial interface (programming adapter required) 9600 BPS, no parity, 8 data bits, 1 stop bit |
| Input/Output |
| Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | 0 ... 1 V |
| 1 Level | 4 V ... UB |
| Input impedance | > 12 kΩ |
| Output rated operating current | < 12 mA |
| Pulse length | 0.5 ... 300 ms (level 1) |
| Pulse interval | ≥ 62.5 ms (level 0) |
| Synchronization frequency | |
| Common mode operation | ≤ 16 Hz |
| Multiplex operation | ≤ 17 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) |
| Input |
| Input type | 1 program input |
| Level (evaluation limit 1) | 0 ... 1 V |
| Level (evaluation limit 2) | 4 V ... UB |
| Input impedance | > 12 kΩ |
| Pulse length | 2 ... 10 s |
| Output |
| Output type | 1 analog output 0 ... 10 V |
| Resolution | evaluation range [mm]/4000, but ≥ 0.4 mm |
| Deviation of the characteristic curve | ≤ 0.2 % of full-scale value |
| Repeat accuracy | ≤ 0.1 % of full-scale value |
| Load impedance | ≥ 500 Ohm |
| Temperature influence | ≤ 1.5 % of full-scale value |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose |
| CSA approval | cCSAus Listed, General Purpose |
| Ambient conditions |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Mechanical specifications |
| Connection type | Connector M12 x 1 , 5-pin |
| Protection degree | IP67 |
| Material | |
| Housing | PA-GF35 |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Mass | 120 g |