| General specifications |
| Detection type | photoelectric sampling |
| Pulse count | max. 5000 |
| Functional safety related parameters |
| MTTFd | 140 a |
| Mission Time (TM) | 20 a |
| L10h | 70 E+9 at 6000 rpm |
| Diagnostic Coverage (DC) | 0 % |
| Electrical specifications |
| Operating voltage | 10 ... 30 V DC |
| No-load supply current | max. 50 mA |
| Output |
| Output type | RS 422, incremental |
| Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected |
| Output frequency | max. 200 kHz |
| Rise time | 100 ns |
| Connection |
| Connector | type 9416, 12-pin |
| Cable | ∅7.8 mm, 6 x 2 x 0.14 mm2, 1 m |
| Standard conformity |
| Protection degree | DIN EN 60529, IP54 |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
| Approvals and certificates |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Ambient conditions |
| Operating temperature | |
| Glass disk | -5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable |
| Plastic disk | -5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable |
| Storage temperature | |
| Glass disk | -40 ... 100 °C (-40 ... 212 °F) |
| Plastic disk | -40 ... 70 °C (-40 ... 158 °F) |
| Mechanical specifications |
| Material | |
| Housing | powder coated aluminum |
| Flange | 3.1645 aluminum |
| Shaft | Stainless steel 1.4305 / AISI 303 |
| Mass | approx. 280 g |
| Rotational speed | max. 12000 min -1 |
| Moment of inertia | ≤ 35 gcm2 |
| Starting torque | ≤ 1 Ncm |
| Shaft load | |
| Angle offset | 1 ° |
| Axial offset | max. 1 mm |