Serviceline Industrial Sensors
Serviceline Explosion Protection

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O KT-MB-GT2AD.FF.IO

KT-MB-GT2AD.FF.IO
  • System integration kit for Advanced Diagnostics
  • PCS integration via Diagnostic Manager or device DTM
  • Simple automatic setup of Advanced Diagnostics
  • Alarm handling and integrated I/O for cabinet monitoring/control
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Installation in Zone 2

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  KT-MB-GT2AD.FF.IO

General specifications
Design / MountingMotherboard based
Supply
Rated voltage19.2 ... 35 V DC SELV/PELV
Rated current210 ... 120 mA
Power dissipationmax. 4.2 W
Fieldbus connection
Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 114
ITK version6
Implementationresource block 1x RS
function block 4x MDI, 1x MDO, 1x MAI, 1x DI
transducer block 16x ADM TB, 1x IO TB
Firmware updateEthernet
Polaritypolarity-sensitive
Rated voltage9 ... 35 V SELV/PELV
Rated current0 mA
Connection to power link
Connection
Ethernet Interface
Rated voltagemax. 35 V SELV/PELV
Port100 BASE-TX
ProtocolTCP/IP and UDP/IP
ServicesICMP , DHCP , AutoIP , HTTP
Connection typeRJ-45 socket, 8-pin
Transfer rate100 MBit/s
Diagnostic Bus
Connectiononly for the connection to protected circuits
Rated voltagemax. 35 V
Number of Diagnostic Bus Channels2
Number of Diagnostic Modules/Channel31 Using Ethernet Interface , 8 Using Fieldbus Interface
Terminationintegrated
Cable length/Channel30 m
Indicators/operating means
LED ERRred: Hardware fault
LED PWRgreen: Power on
Fault signalbuzzer on
LINK/ACTyellow
CH1, CH2yellow: diagnostic bus activity
Inputs
Input I, II
Input typeselectable: Frequency input , NAMUR/mechanical contact
Frequency
Connectiononly passive load
Rated voltagemax. 35 V
Input frequency0.3 Hz to 1 kHz
Pulse durationmin. 50 µs
Accuracy± 1 %
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input III, IV
Input typeNAMUR/mechanical contact
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input V
Input typeselectable: diagnostic bus CH 1 alarm input , NAMUR/mechanical contact
Alarm Input
Connectiononly passive load
Rated voltagemax. 35 V
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input VI
Input typeselectable: diagnostic bus CH 2 alarm input , NAMUR/mechanical contact
Alarm Input
Connectiononly passive load
Rated voltagemax. 35 V
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input VII, VIII
Input typeselectable: Pt100 4-wire temperature input , NAMUR/mechanical contact
Temperature
Connectiononly passive load
Rated voltagemax. 35 V
Measurement range-50 ... 90 °C (-58 ... 194 °F)
Accuracy1 K
Measuring current1 mA
Lead resistance4.2 Ω per line
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Humidity
Measurement range0 ... 95 % RH
Accuracy2 % RH
Resolution0.04 %
Outputs
Output I
Output typeselectable: diagnostic bus CH 1 , relay , NO contact
Contact loading250 V AC/ 6 A resistive load
Mechanical life1 x 105 switching cycles
Response timeturn-on time 7 ms , turn-off time 3 ms
Switching frequency6 min-1 full load, 1200 min-1 without load
Output II
Output typeselectable: diagnostic bus CH 2 , relay , NO contact
Contact loading250 V AC/ 6 A resistive load
Mechanical life1 x 105 switching cycles
Response timeturn-on time 7 ms , turn-off time 3 ms
Switching frequency6 min-1 full load, 1200 min-1 without load
Output III
Output typeselectable: common alarm , volt-free contact , NC contact
Connectiononly for the connection to protected circuits
Voltage50 V DC
Currentmax. 1 A
Output IV
Output typecommon alarm , buzzer
Galvanic isolation
All circuits/FEfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output I, II/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 250 Veff
Ethernet/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Ethernet/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Fieldbus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Diagnostic Bus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 73/23/EECEN 61010-1:2010
Standard conformity
Galvanic isolationIEC 62103
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F) hazardous area
-40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance5 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Housing materialPolycarbonate
Degree of protectionIP20
Mass500 g
Dimensions
Heightsee dimensions
Widthsee dimensions
Depthsee dimensions
MountingDIN rail mounting
Data for application in connection with hazardous areas
FOUNDATION Fieldbus
ConnectionFor connection to circuits with safe limited voltage according to IEC 60079-11:2011, type of protection "ic"
Voltage Uimax. 35 V
CertificateTÜV 14 ATEX 115980 X
MarkingMotherboard MB-FB-GT.AD.FF.IO Ex-Hexagon II 3 G Ex nA nC IIC T4 Gc , Gateway Ex-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx TUN 14.0003X
Approved forMotherboard Ex nA nC IIC T4 Gc , Gateway Ex nA IIC T4 Gc
General information
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.027242692
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027242692
ECLASS 5.127242692
ETIM 9.0EC001604
ETIM 8.0EC001604
ETIM 7.0EC001604
ETIM 6.0EC001604
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: KT-MB-GT2AD.FF.IO

Function

The FieldConnex ® Diagnostic Gateway is the interface between stationary Advanced Diagnostic Modules (ADM) and the control system. It offers access to all ADM data in two ways: via Ethernet and the Diagnostic Manager software or via FOUNDATION Fieldbus H1 and DTM/EDD or both.

The gateway configures itself and automatically detects the ADMs. The Diagnostic Manager automatically finds gateways on the same subnet. The setup of the diagnostic bus and all connected modules is automatic. This significantly simplifies engineering of FieldConnex ® Advanced Diagnostics.

Inputs for frequency, temperature, humidity, and NAMUR sensors and 2 relay contacts allow control of the control cabinet. The cabinet and physical layer diagnostics become easy-to-manage plant assets.

Informative Literature: KT-MB-GT2AD.FF.IO

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB
Application Report - Systematic Monitoring of Control CabinetsENGPDF199 KB

Product Documentation: KT-MB-GT2AD.FF.IO

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Quick Start Guide Diagnostic ManagerENGPDF1520 KB
Safety and Security Documentation
Instruction manualENGPDF230 KB
Manuals
ManualENGPDF25397 KB
Software Information
Release NoteENGPDF284 KB
End-user software license agreement (EULA)ENGPDF37 KB

Approvals: KT-MB-GT2AD.FF.IO

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada FMFM20CA0005XALLPDF400 KB
China SITIIAS CCC Ex Certificate2020322310003538 (Singapore)ALLPDF1423 KB
Europe TUV Nord ATEX Category 3 Zone 2TÜV 14 ATEX 115980 XALLPDF474 KB
TUV Nord Zone 2IECEx TUN 14.0003XALLLINK---
USA FMFM20US0009XALLPDF419 KB
Worldwide Fieldbus FoundationIT082700ALLPDF50 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0596DALLPDF1041 KB

Software: KT-MB-GT2AD.FF.IO

Language Selection:
Device Description Files/DriversRelease InfoFile TypeFile Size
DD/CFF files HD2-GT-2AD.FF.IO / DD/CFF-Dateien HD2-GT-2AD.FF.IO0102/010102ZIP266 KB
Software Tools
Diagnostic Gateway FF DTM / Diagnostic Gateway FF DTM2.2.3.3527ZIP65378 KB
Pepperl+Fuchs Discovery and Configuration Tool (PFDCT) / Pepperl+Fuchs Discovery and Configuration Tool (PFDCT)2.4.0.412ZIP4773 KB

Associated Products: KT-MB-GT2AD.FF.IO

Matching System Components
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europepa
Matching System Components

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Accessories
Software user interface for Advanced Diagnostic Modules, Simultaneous access to all ADMs of a plant, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PA, Automatic setup of diagnostic systempa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa

Ethernet-APL enables continuous communication across all hierarchy levels. Learn more about the pioneering technology …

RSS Info Service for PANOS Updates

Stay informed when a new software update of PANOS, the operating system for Ethernet-APL switches, is released: With our RSS Feed you will get an email notfication in your inbox immediately after an update has been released.

From decisions to planning, installation, and commissioning up to operation and maintenance: Discover how to make the most out of your fieldbus infrastructure …