  • 12 outputs Ex ib IIC
  • Segment Protector in Zone 1
  • Instruments in Zone 1
  • Short-circuit protection per output
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Power, Com, and Error LEDs
  • T-connector for easy installation and maintenance
  • Test points for easy troubleshooting

Datasheet as PDF in following languages:


Technical Data: R3-SP-IBD12

Fieldbus interface
Main cable (Trunk)
Rated voltage14.5 ... 24 V DC
Rated currentmax. 4.5 A
Outputs
Number of outputs12
Number of devices per output1
Rated voltagemin. 10.5 V , max. 24 V
Rated currentmax. 34 mA
Short-circuit currentmax. 47 mA
Self current consumptiontypical 20 mA , max. 25 mA
Voltage drop main cable/outputsmax. 4 V
Voltage drop trunk In/Out0 V
Terminating resistorexternal type M-FT-IBD 100 Ω +/- 10 %
Indicators/operating means
LED ERRred: short-circuit
LED PWRgreen: Fieldbus voltage > 10 V
LED COMyellow: bus activity
Directive conformity
Electromagnetic compatibility
Directive 2004/108/ECEN 61326-1:2006
Standard conformity
Electromagnetic compatibilityNE 21:2006
Protection degreeIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-50 ... 85 °C (-58 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeremovable screw terminals with retaining screws
Core cross-sectionmax. 2.5 mm2 /AWG 12-24
Housing materialPolycarbonate
Protection degreeIP20
Mass250 g
Dimensionssee dimensions
MountingDIN mounting rail , according to DIN EN 60715
Data for application in connection with Ex-areas
EC-Type Examination CertificatePTB 10 ATEX 2034 , PTB 10 ATEX 2018X
Group, category, type of protection, temperature classEx-Hexagon II 2G Ex ib IIC T4 ,
Ex-Hexagon II (2)D [Ex ib] IIIC
Main cable (Trunk)for connection to the DART Fieldbus System acc. to System Certificate PTB 10 ATEX 2034
OutputsEntity
Voltage23 V
Current47 mA
Power1.08 W
Inductancegas group IIC 170 µH
gas group IIB 1 mH
Capacitancegas group IIC 60 nF
gas group IIB 470 nF
Directive conformity
Directive 94/9/ECEN 60079-0:2009 , EN 60079-11:2007 , EN 61241-11:2006
International approvals
IECEx approvalIECEx PTB 12.0024X IECEx PTB 12.0021X
Approved forEx ib IIC T4
[Ex ib] IIIC
Certificates and approvals
FOUNDATION FieldbusFF-846
Marine approvalpending

CAD+CAE: R3-SP-IBD12

CADFile TypeFile Size
Abmessungszeichnung 2D (DXF)/Dimension drawing 2D (DXF)ZIP925 KB

Approvals+Certificates: R3-SP-IBD12

CertificatesCertificate No.File TypeFile Size
Europe PTB ATEXPTB 10 ATEX 2018XPDF656 KB
Worldwide Fieldbus FoundationDC070901LINK---
Europe Pepperl+Fuchs ATEX Declaration of ConformityPF 12 CERT 2276PDF91 KB
Europe PTB II 2 G II (2) G II 3 (2) G II 3 G ATEXPTB 10 ATEX 2034PDF894 KB
PTB IECEx Certificate of ConformityIECEx PTB 12.0024LINK---

Associated Products: R3-SP-IBD12

Matching system componentsName
KT-MB-FB-D-4RDART High-Density Power Hub, Common Interface
KT-MB-FB-D-4R.GENDART High-Density Power Hub, Generic Interface
KT-MB-FB-D-4R.YODART High-Density Power Hub for Yokogawa ALF 111
KT-MB-GTB-D-2PSDART Compact PROFIBUS Power Hub and Segment Coupler