Termination Boards





View All Products in Group: Termination Boards


First PagePrevious Page1 - 10 ( of 94 ) Next PageLast Page
Items per Page:
ProductShort Description
Termination Board for Honeywell Safety Manager
FC-GPCD-SDI16-PF
System Board for Honeywell Safety Manager RIO I.S., For 16-channel card SDI-1624, 8 plug-in positions, Recommended module: HiC2822 (DI), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager RIO I.S.
FC-GPCS-RIO16-PF
System Board for Honeywell Safety Manager RIO I.S., For 16-channel card RUSIO, 16 plug-in positions, Recommended modules: HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin
Termination Board for Honeywell Safety Manager
FC-GPCS-SAI16-PF
System Board for Honeywell Safety Manager RIO I.S., For 16-channel card SAI-1620m, 16 plug-in positions, Recommended module: HiC2025 (AI), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager
FC-GPCS-SAO08-PF
System Board for Honeywell Safety Manager RIO I.S., For 4 pieces 2-channel card SAO-0220m, 8 plug-in positions, Recommended module: HiC2031 (AO), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager
FC-GPCS-SDI16-PF
System Board for Honeywell Safety Manager RIO I.S., For 16-channel cards SDIL-1608 and SDI-1624, 16 plug-in positions, Recommended modules: HiC2821 (SIL2), HiC2851 (SIL3), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager
FC-GPCS-SDO08-PF
System Board for Honeywell Safety Manager RIO I.S., For 8-channel card SDO-0824, For 8 modules, Recommended module: HiC2871 (DO), Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager
FC-GPDD-SAI16-PF
System Board for Honeywell SMS, For 16-channel card SAI-1620m, 8 plug-in positions, Recommended module: HiD2030 (AI), HiD2082 (Temp.), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Termination Board for Honeywell Safety Manager
FC-GPDS-SAI16-PF
System Board for Honeywell Safety Manager, For 16-channel card SAI-1620m, 16 plug-in positions, Recommended modules: HiD2029SK (AI), HiD2081 (Temp.), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
HART Termination Board
FI-DO-R-Y41610
16-channel, Connection board for K-System HART Multiplexer, Interface for series connections, Integrated 250 Ω resistor
HART Termination Board
FI-DO-R-Y49092
16-channel, Connection board for K-System HART Multiplexer, Interface for series connections
First PagePrevious Page1 - 10 ( of 94 ) Next PageLast Page