Safety Light Grids

View All Products in Group:
Safety Light Grids
![]() | ![]() | ![]() | ![]() | |||||||||||
| Product | Short Description |
|---|---|
| Safety light grid mirror SLC-2400-M | Deflecting mirror for multi-sided protection safety layouts using SLC series safety light grids |
| Safety light grid with integrated control unit SLC-3 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 3, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs |
| Safety light grid with integrated control unit SLC-3/129/151 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Protection degree IP67, Effective detection range: 0.2 ... 20 m, Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Number of beams: 3, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs |
| Safety light grid SLC-3/133 | ATEX-approval for zone 2 and zone 22, Sensing range up to 20 m, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , Cable diameter ∅5.5 ... 13 mm , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 3, Operating mode: can be selected with or without start/restart disable |
| Safety light grid with integrated control unit SLC-3/151 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Effective detection range: 0.2 ... 20 m, Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Number of beams: 3, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs |
| Safety light grid with integrated control unit SLC-3/31 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 3, Operating mode: can be selected with or without start/restart disable, Safety output: 2 relay outputs, force-guided NO-contact |
| Safety light grid mirror SLC-350-M | Deflecting mirror for multi-sided protection safety layouts using SLC series safety light grids |
| Safety light grid with integrated control unit SLC-4 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Start/Restart disable , Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 4, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs |
| Safety light grid with integrated control unit SLC-4/129/151 | Sensing range up to 20 m, 2, 3, and 4-beam design, Beam distance 300, 400 and 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Protection degree IP67, Effective detection range: 0.2 ... 20 m, Connection: Emitter: M12 connector, 4-pin Receiver: M12 connector, 8-pin, Number of beams: 4, Operating mode: can be selected with or without start/restart disable, Safety output: 2 separated fail safe semiconductor outputs |
| Safety light grid SLC-4/133 | ATEX-approval for zone 2 and zone 22, Sensing range up to 20 m, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Effective detection range: 0.2 ... 20 m, Connection: M20 cable gland , Cable diameter ∅5.5 ... 13 mm , terminal compartment with screw terminals, lead cross-section max. 1.5 mm2 , Number of beams: 4, Operating mode: can be selected with or without start/restart disable |
![]() | ![]() | ![]() | ![]() | |||||||||||