SMART Transmitter Power Supply KCD2-STC-Ex1.SP

KCD2-STC-Ex1.SP
  • 1-channel isolated barrier
  • 24 V DC supply (Power Rail)
  • Input for 2-wire SMART transmitters and current sources
  • Output for 4 mA ... 20 mA or 1 V ... 5 V
  • Housing width 12.5 mm
  • Connection via spring terminals with push-in connection technology
  • Up to SIL 2 (SC 3) acc. to IEC/EN 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  KCD2-STC-Ex1.SP

General specifications
Signal typeAnalog input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3
Supply
ConnectionPower Rail or terminals 9+, 10-
Rated voltage19 ... 30 V DC
Ripple≤ 10 %
Rated current≤ 45 mA at 24 V and 20 mA source mode output
Power dissipation≤ 800 mW
Power consumption≤ 1.1 W
Input
Connection sidefield side
Connectionterminals 1+, 2-; 3+, 4-
Input signal4 ... 20 mA limited to approx. 26 mA
Open circuit voltage/short-circuit currentterminals 1+, 2-: 22 V / 26 mA
Voltage dropterminals 3+, 4- : approx. 5 V
Available voltageterminals 1+, 2-: ≥ 15 V at 20 mA ; ≥ 18 V at 4 mA
Output
Connection sidecontrol side
Connectionterminals 5-, 6+
terminals 5-, 8+ for HART resistor
Load0 ... 350 Ω (source mode)
Output signalsource mode: 4 ... 20 mA or 1 ... 5 V (internal resistor: 250 Ω, 0.1 %)
sink mode: 4 ... 20 mA, operating voltage 10 ... 30 V
For additional internal or external loads (e. g. terminal +8) the voltage drop has to be considered, e. g. 250 Ω x 20 mA = 5 V.
Ripple20 mV rms
Transfer characteristics
Deviationat 20 °C (68 °F)
< 0.1 % of full scale, incl. non-linearity and hysteresis (source mode and sink mode 4 ... 20 mA)
≤ ± 0.2 % incl. non-linearity and hysteresis (source mode 1 ... 5 V)
Influence of ambient temperature< 2 µA/K (-20 ... 70 °C (-4 ... 158 °F)); < 4 µA/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode and sink mode 4 ... 20mA)
< 0.5 mV/K (-20 ... 70 °C (-4 ... 158 °F)); < 1 mV/K (-40 ... -20 °C (-40 ... -4 °F)) (source mode 1...5 V)
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)
control side into the field side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB)
Settling time≤ 50 ms
Rise time/fall time≤ 10 ms
Galvanic isolation
Input/Outputbasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplybasic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLED
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2017
EN 61326-3-2:2018
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2019
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP20
Connectionspring terminals
Massapprox. 100 g
Dimensions12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
Height124 mm
Width12.5 mm
Depth114 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateCESI 06 ATEX 021 X
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
InputEx ia
Supply
Maximum safe voltage250 V AC (Attention! Um is no rated voltage.)
Equipmentterminals 1+, 2-
Voltage25.2 V
Current100 mA
Power630 mW
Internal capacitance5.7 nF
Internal inductancenegligible
Equipmentterminals 3+, 4-
Voltage30 V
Current128 mA
Power1000 mW
Voltage7.2 V
Current100 mA
Power25 mW
Internal capacitance5.7 nF
Internal inductancenegligible
CertificateCESI 19 ATEX 021 X
MarkingEx-Hexagon II 3G Ex ec IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN IEC 60079-7:2015+A1:2018
International approvals
FM approval
FM certificateFM 18 CA 0116 X , FM 19 US 0117 X
Control drawing116-0469 (cFMus)
UL approvalE106378
Control drawing116-0459 (cULus)
IECEx approval
IECEx certificateIECEx CES 06.0001X
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Ex ec IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210119
ECLASS 12.027210119
ECLASS 11.027210119
ECLASS 10.0.127210119
ECLASS 9.027210119
ECLASS 8.027210119
ECLASS 5.127210119
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: KCD2-STC-Ex1.SP

This isolated barrier is used for intrinsic safety applications.

The device supplies 2-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.

It transfers the analog input signal to the safe area as an isolated current value.

Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.

Selectable output of current source, sink mode, or voltage output is available via DIP switches.

If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 6 and 8 can be used.

Test sockets for the connection of HART communicators are integrated into the terminals of the device.

Datasheet: KCD2-STC-Ex1.SP

DatasheetFile TypeFile Size
Datasheet KCD2-STC-Ex1.SPPDF755 KB
Fiche de données KCD2-STC-Ex1.SPPDF778 KB
Datenblatt KCD2-STC-Ex1.SPPDF757 KB
Datasheet KCD2-STC-Ex1.SPPDF828 KB
Hoja de datos KCD2-STC-Ex1.SPPDF782 KB

Documents: KCD2-STC-Ex1.SP

ManualsFile TypeFile Size
ManualPDF3685 KB
HandbuchPDF3693 KB
Instruction manuals
ИнструкцииPDF173 KB
Instruction manual / BetriebsanleitungPDF337 KB
Návod k poużitíPDF168 KB
Instruktions manualPDF167 KB
Instruction manualPDF172 KB
KasutusjuhendPDF162 KB
KäyttöohjePDF162 KB
Manuel d'instructionsPDF169 KB
BetriebsanleitungPDF173 KB
Οδηγίες χρήσηςPDF176 KB
HandleidingPDF167 KB
Instruction manual / BetriebsanleitungPDF165 KB
Használati útmutatóPDF169 KB
Manuale di istruzioniPDF167 KB
Lietošanas pamācībaPDF166 KB
Instrukciju vadovasPDF168 KB
Instrukcja obsługiPDF169 KB
Manual de instruçõesPDF168 KB
Manual de utilizarePDF167 KB
Návod na poużitiePDF167 KB
Navodila za uporaboPDF164 KB
Manual de instruccionesPDF168 KB
ManualPDF164 KB
Documents
Functional Safety ManualPDF2002 KB
Handbuch funktionale SicherheitPDF2021 KB

CAD+CAE: KCD2-STC-Ex1.SP

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP3048 KB

Approvals+Certificates: KCD2-STC-Ex1.SP

CertificatesFile TypeFile Size
Australia SIMTARS Group IPDF424 KB
Brasil TUV Rheinland BrazilPDF466 KB
Brasil TUV Rheinland BrazilPDF444 KB
Canada FMPDF2690 KB
Certificates Product-Specific / Zertifikate produktspezifischPDF142 KB
Certificates Product-Specific / Zertifikate produktspezifischPDF143 KB
China SITIIAS CCC Ex CertificatePDF2226 KB
Europe CESI ATEX Category 3 G Certificate of CompliancePDF447 KB
Europe CESI II (1) D II (1) G I (M1) ATEXPDF622 KB
India PESO (India) CCOEPDF100 KB
Korea KOSHA [Ex ia]PDF206 KB
SITIIAS CCC Ex CertificatePDF2122 KB
South Africa MASCPDF656 KB
USA Canada UL cULus Hazardous Location Certificate of Compliance UL E106378 ULPDF433 KB
USA FMPDF2447 KB
United Arab Emirates SGS Gulf Limited ECASExPDF603 KB
United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1)PDF168 KB
Worldwide CESI IECEx Certificate of ConformityLINK---
Worldwide TUV Rheinland Functional Safety CertificatePDF620 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)PDF237 KB
EU Declaration of Conformity (P+F)PDF232 KB
EU Declaration of Conformity (P+F)PDF230 KB
EU Declaration of Conformity (P+F)PDF232 KB
UK Declaration of Conformity (P+F)PDF202 KB
EU Declaration of Conformity (P+F)PDF228 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF230 KB
EU-Konformitäterklärung (P+F)PDF232 KB
EU Declaration of Conformity (P+F)PDF238 KB
EU Declaration of Conformity (P+F)PDF228 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF230 KB
EU Declaration of Conformity (P+F)PDF231 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF232 KB
EU Declaration of Conformity (P+F)PDF233 KB
EU Declaration of Conformity (P+F)PDF231 KB
EU Declaration of Conformity (P+F)PDF230 KB
EU Declaration of Conformity (P+F)PDF232 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF229 KB
EU Declaration of Conformity (P+F)PDF231 KB

Associated Products: KCD2-STC-Ex1.SP

Matching System Components

Interface for Power Rail, Supply current ≤ 4 A, Replaceable fuse, Relay contact output, reversible, LED status indicationpa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 2 m (6 foot), simple to customize to application space, Eliminates daisy-chainspa

35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 0.8 m (2.6 ft), simple to customize to application space, Eliminates daisy-chainspa
35 mm DIN mounting rail with 3-conductor insert, Provides DC supply voltage to all equipped K-System modules, Standard length 1.6 m (5 foot), simple to customize to application space, Eliminates daisy-chainspa
Cable trunking is integrated in the mounting profile, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aidspa
Cable trunking with integrated Power Rail UPR-03, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Provides DC supply voltage to all equipped K-System modules, Standard length 1.8 m (5.8 ft), simple to customize to application space, With end caps UPR-E, cover and mounting aidspa
Accessories
2-pin spring terminal with push-in connection technology, For KC modules of K-System, Integrated test sockets for connection of HART communicators, Packaging unit: 3 pieces green, 2 pieces bluepa
2-pin spring terminal with push-in connection technology, For KC modules of K-System, Integrated test sockets for connection of HART communicators, Packaging unit: 5 pieces bluepa
2-pin spring terminal with push-in connection technology, For KC modules of K-System, Integrated test sockets for connection of HART communicators, Packaging unit: 5 pieces greenpa
Coding of K-System terminal blocks, Coding of LB/FB-System front sockets, Packaging unit: 20 x 6 coding pinspa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.