Not available for purchase: Code rail, polyester laminate, Flexible installation by means of alu profile- or mounting bracket system, High chemical resistance, Low weightfa
Not available for purchase: Code rail, stainless steel, Flexible installation by means of alu profile- or mounting bracket system, High mechanical stability, Suitable for applications with wide temperature variationsfa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 15 V DC, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC , loop powered, Type: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Voltage: ≥ 15 Vpa
Not available for purchase: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
Not available for purchase: Protection module for 1 supply line, Type 2 acc. to EN 61643-11, Exchange device for surge protection barrier M-LB-*.275*.D, Easy replacement of protection modules wihtout tools, High discharge capacity, Module can be exchanged under voltage (hot swap), Device type: type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1, Number of protected supply lines: 1pa
Not available for purchase: Spring disk coupling, Very high torsion spring stiffness, Suitable up to 12.000 rpm, Well misalignment compensation, Vibration- isolating, Electrically insulatingfa
Pepperl+Fuchssuppliesprocessautomationindustrycompanies with provencomponents for a diverserange of applications These include the oil and gasindustry, petrochemical, chemicalindustry, pharmaceuticalindustry, as well as wastewatertreatmentplants and powertechnology ... ApplicationIndexOffshore+MarineOil+GasChemicalIndustryPharmaceuticsPowerIndustriesWater+WasteWater ...
Pepperl+Fuchs is the idealpartner for factoryautomation & processautomationprojects that requireindustry-specific technologiesMarket-based, customer-focusedproductsmean that you getsolutionsoptimized for yourindustrialautomationoperations ... AutomotiveIndustryMobileEquipmentRenewableEnergyMaterialHandlingPrint and PaperIndustryPackagingIndustryElectronicsIndustryProcessEquipmentEntranceAutomationExplosionProtectionOffshore+MarineOil+GasChemicalIndustryPharmaceuticsPower ...
As a globalsensormanufacturer, Pepperl+Fuchsprovides the highest-qualitysensors for automationsolutionsPepperl+Fuchs is the idealpartner for factoryautomationprojects that requireindustry-specific technologies ... ! ViewApplicationIndexMachine + PlantEngineeringAutomotiveIndustryMobileEquipmentRenewableEnergyMaterialHandlingPrint and PaperIndustryPackagingIndustryElectronicsIndustryProcessEquipmentEntranceAutomation ...
Yourtechnical and productquestions are answered by Pepperl+Fuchsexperts in one businessday! ... . * Pepperl+Fuchsmakeseveryeffort to provide an answer that is helpful and relevant to you. Yourquestion is typicallyanswered in one businessday. Occasionally, an answer is delayed. In these cases, we are oftenresearchingyourquestion, conferring ...
Ourproductselectortoolcanhelp you quicklyfind the rightproduct for yourapplication ... . Simplyrefineyourselectionsstep-by-stepuntil you reach the desiredproduct . Resete-newsSubscribe to ournewsletter and receiveregularnews and interesting information around the world of automation. Subscribe ...
... for almosteveryapplication. These details and more are reflected in ourordernumber, the Pepperl+Fuchstypecode. The typecode is madeup of threesections (seprerated by hyphens), each of whichrefers to specific productfeatures. Below, we will explain ...
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.