UHF RFID read/write device with IO-Link, India |
General specifications | ||
---|---|---|
Operating frequency | 865 MHz … 867 MHz: India Transmission licenses for other countries on request |
|
Emitted power | 3 … 100 mW ERP adjustable | |
MTBF | 127 a (Operation at +40 °C) | |
Indicators/operating means | ||
LED green/red | Solid green: Ready for operation, no IO-Link communication Flashing green (1 Hz): IO-Link operation |
|
LED yellow | Read/write operation successful | |
LED blue | Transmission mode | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC (IO-Link) | |
Current consumption | ≤ 90 mA ( at 24 V DC ) | |
Interface | ||
Interface type | IO-Link | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D | |
Process data | Input 32 Byte Output 32 Byte |
|
Vendor ID | 1 (0x0001) | |
Device ID | 4194820 (0x400204) | |
Data transfer rate | COM3 (230.4 kbits/s) | |
Min. cycle time | 4 ms | |
SIO mode support | no | |
Compatible master port type | Class A Class B |
|
Standard conformity | ||
Degree of protection | EN 60529 | |
Communication interface | IEC 61131-9 / IO-Link V1.1.3 | |
RFID | ISO/IEC 18000-63 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods) -25 ... 60 °C (-13 ... 140 °F) (Continuous transmission mode) |
|
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | connector M12 x 1 | |
Material | ||
Housing | PA 6.6 | |
Base | Aluminum | |
Mass | 700 g | |
Dimensions | ||
Height | 47 mm | |
Width | 165 mm | |
Length | 165 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27280401 |
ECLASS 12.0 | 27280401 |
ECLASS 11.0 | 27280401 |
ECLASS 10.0.1 | 27280401 |
ECLASS 9.0 | 27280401 |
ECLASS 8.0 | 27280401 |
ECLASS 5.1 | 27280401 |
ETIM 9.0 | EC002998 |
ETIM 8.0 | EC002998 |
ETIM 7.0 | EC002998 |
ETIM 6.0 | EC002998 |
ETIM 5.0 | EC002998 |
UNSPSC 12.1 | 43211710 |
The read/write device operates in the UHF frequency range and is optimized for use in industrial applications involving shorter distances. The device reads and writes passive tags acc. to EPC Generation 2 ( ISO/IEC 18000-63). The read/write device is compliant with the relevant transmission regulations.
Wide range of options supported for filtering data. The read/write device has an IO-Link interface and is connected via a M12 connector. The user can monitor the status of the read/write device using the integrated LEDs.
The read/write device has a typical detection range of around 1 meter; this range is determined by the tag used and can be adjusted by configuring the transmission power. Other influencing factors include the setup and installation of the specific application and the surrounding materials, particularly metal. The read and write distances for the relevant tag, which are detailed separately, have been established in a test laboratory under ideal conditions. For the actual read and write distances under real conditions, the combination of read/write device and tag must be tested in the desired application.
Manuals | Language | File Type | File Size |
---|---|---|---|
Manual IUT-F191-IO-V1-FR* | ENG | 9393 KB | |
Parameter Information | |||
IO-Link Parameter Datasheet IUT-F191-IO-V1-FR1-04 / IO-Link-Parameter-Datenblatt IUT-F191-IO-V1-FR1-04 | ALL | 541 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1114 KB |
Certificates | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
IO-Link Manufacturer Declaration | CERT-6856 | ALL | 363 KB | |
India Radio Approval | ETA-SD-20230706802 | ALL | 61 KB |
Device Description Files/Drivers | Release Info | File Type | File Size |
---|---|---|---|
IODD for IUT-F191-IO-V1-FR1-04 / IODD für IUT-F191-IO-V1-FR1-04 | V1.00.000 / 2023-05-02 | ZIP | 170 KB |
Add-On instructions for Rockwell Automation Studio 5000 software. For parameterization and read/write functionality on IUT-...-B40, IUT-...IO and IQT3-...-IO Readers / Software Tool_a | 2.0 Dec 19, 2023 | ZIP | 227840 KB |
Function blocks TIA Portal (S7-1200/1500) for the RFID device IUT-F191-IO-V1 (IO-Link) when using the Easy Mode / Funktionsbausteine TIA Portal (S7-1200/1500) für das RFID-Gerät IUT-F191-IO-V1 (IO-Link) bei der Verwendung des Easy Modes | V1.0 | ZIP | 18780 KB |
Function blocks TIA Portal (S7-1200/1500) for the RFID device IUT-F191-IO-V1 (IO-Link) when using the Expert Mode / Funktionsbausteine TIA Portal (S7-1200/1500) für das RFID-Gerät IUT-F191-IO-V1 (IO-Link) bei der Verwendung des Expert Modes | V2.1 | ZIP | 15120 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|