Serviceline Industrial Sensors
Tél.: +32 (0)3-644 25 00
Support en ligne pour la protection contre le risque d’explosion

Control interface unit IC-KP-B17-AIDA1

IC-KP-B17-AIDA1
  • Max. 4 read/write heads connectable
  • Alternative 2 read/write heads and 2 trigger sensors can be connected
  • LED status indicator of bus communication and read/write heads
  • TCP/IP, MODBUS/TCP, EtherNet/IP and PROFINET IO protocol
  • Connector acc. to AIDA specifications
  • Integrated switch allows line topology

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Téléchargez ici la fiche technique complète en PDF:


Caractéristiques techniques  IC-KP-B17-AIDA1

Description produit
IDENTControl control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocols
General specifications
Number of read/write headsmax. 4
alternative 2 read/write heads and 2 trigger sensors
UL File NumberE87056
Functional safety related parameters
MTTFd110 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LEDs CH1, CH2, CH3, CH4Status indicator for read/write heads
green: command at read/write head active
yellow: approx. 1 second long, if command was successfully executed
LED PWR/ERRgreen: power on
red: PROFINET bus failure
LED Link1/Link2green: network connection
LED Trafficgreen: flashes in rhythm with the transmitted data
LC displaytwo-line multi-function display with 12 characters per line
configuration of the control interface and display of connected read/write heads as additional pictograms; easy and direct selection of operating commands
Button4 keys: ESC, up, down and return
Electrical specifications
Rated operating voltage20 ... 30 V DC , PELV
Ripple≤ 10 % at 30 V DC
Current consumption≤ 8 A incl. read/write heads
Power consumption3.5 W Without read/write heads
Galvanic isolationbasic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff
Interface 1
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Interface 2
Physical Ethernet
ProtocolSMTP
HTTP
TCP/IP (Port 10000)
MODBUS/TCP
EtherNet/IP
PROFINET IO
Transfer rate10 MBit/s or 100 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-30 ... 80 °C (-22 ... 176 °F)
Climatic conditionsair humidity max. 96 %
Shock and impact resistanceOscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6
Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27
Mechanical specifications
Degree of protectionIP67
ConnectionRead/write heads: shielded, 4-pin, M12 connector
Power supply: MSTB AIDA
Protective earth: M6 earthing screw
Ethernet: RJ-45 AIDA
Material
Housingpowder coated aluminum
Installationsnap-on to 35 mm standard rail or screw fixing
Massapprox. 1000 g

Documents: IC-KP-B17-AIDA1

ManualsLangueType de fichierTaille
Manual IC-KP-B17-AIDA1ENGPDF4040 KB
Manual Read / Write Ranges and Passing Speeds RFIDENGPDF3640 KB
Handbuch IC-KP-B17-AIDA1GERPDF4086 KB
Handbuch Schreib- und Leseabstände und Vorbeifahrgeschwindigkeiten RFIDGERPDF3642 KB
Instruction leaflets
Device mounting / GerätemontageALLPDF917 KB
Short instructions, safety information
Quick Start Guide IC-KP-*ENGPDF1019 KB
Kurzanleitung IC-KP-*GERPDF1014 KB

Approvals+Certificates: IC-KP-B17-AIDA1

Statements of complianceIdentificationType de fichierTaille
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1845BPDF162 KB
Certificates
Australia Declaration of ConformityACMA Supplier's declaration of conformityPDF730 KB
Korea Radio ApprovalMSIP-REI-PF1-ICKPB17AIDA1PDF358 KB
US CA ULE87056LINK---

Commissioning: IC-KP-B17-AIDA1

Commissioning examplesLangueType de fichierTaille
Commissioning IC-KP-B17-AIDA Profinet S7 Multiframe ParameterENGPDF3442 KB
Commissioning IC-KP-B17-AIDA Profinet S7 Singleframe ParameterENGPDF3044 KB
Inbetriebnahme IC-KP-B17-AIDA Profinet S7 Multiframe ParameterGERPDF3264 KB
Inbetriebnahme IC-KP-B17-AIDA Profinet S7 Singleframe ParameterGERPDF3044 KB
Commissioning files
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IPH-...-V1 for complete reading and writing of the IPC03 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IPH-...-V1 zum vollständigen Lesen und Schreiben des IPC03 DatenträgersALLZIP2184 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC21 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC21 DatenträgersALLZIP2180 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC22 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC22 DatenträgersALLZIP2181 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC24 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC24 DatenträgersALLZIP2182 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC33 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC33 DatenträgersALLZIP2176 KB
Function block Step 7 Classic for the evaluation unit IC-KP-Bxx (Profinet + Profibus) with the RFID heads IQH1-...-V1 for complete reading and writing of the IQC35 data carrier / Funktionsbaustein Step 7 Classic für die Auswerteeinheit IC-KP-Bxx (Profinet + Profibus) mit den RFID-Köpfen IQH1-...-V1 zum vollständigen Lesen und Schreiben des IQC35 DatenträgersALLZIP2180 KB
Simatic S7 function block V3.0 Profinet connection IC-KP-B17-AIDA1 and IC-KP-B12-V45 / Simatic S7 Funktionsbaustein V3.0 Profinet Anbindung IC-KP-B17-AIDA1 und IC-KP-B12-V45ALLZIP1174 KB
Step 7 function block S7-300/400 for IC-KP-B17 (Profinet) MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-300/400 für IC-KP-B17 (Profinet) MultiFrame Protokoll UHF-SystemALLZIP8316 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP-B17-AIDA1 MultiFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP-B17-AIDA1 MultiFrame Protokoll UHF-SystemALLZIP1321 KB
Step 7 function block S7-400 with CP for TCP/IP communication IC-KP-B17-AIDA1 SingleFrame protocol UHF-System / Step 7 Funktionsbaustein S7-400 mit CP für TCP/IP Kommunikation IC-KP-B17-AIDA1 SingleFrame Protokoll UHF-SystemALLZIP1271 KB

Produits associés : IC-KP-B17-AIDA1

Accessory of

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa

HF read/write head, ISO 15693, for IDENTControlfa

Read/Write head for IDENTControl, 125 kHz, thread M30 x 1.5fa

Read/Write head for IDENTControl, 125 kHz, VariKont housingfa

Read/Write head for IDENTControl, 125 kHz, thread M18 x 1fa

Read/Write head for IDENTControl, 125 kHz, flat housingfa

Read/Write head for IDENTControl, 125 kHz, square housingfa
UHF read/write head for hazardous areas, for IDENTControl, Canada, USA, and Mexicofa
UHF read/write head for IDENTControl, Europefa
UHF read/write head for IDENTControl, Indiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
UHF read/write head for IDENTControl, Russiafa
UHF read/write head for IDENTControl, Moroccofa
Read/write head for IDENTControl, USA, Canada, Mexico, and Argentinafa
UHF read/write head for IDENTControl, Chinafa
UHF read/write head for IDENTControl, Brazilfa
UHF read/write head for IDENTControl, Japanfa
UHF read/write head for IDENTControl, Australiafa
UHF read/write head for IDENTControl, Thailand and Hong Kongfa
UHF read/write head for IDENTControl, Malaysiafa
UHF read/write head for IDENTControl, Singapore and Vietnamfa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
HF read/write head, ISO 15693, for IDENTControlfa
Read/Write head for IDENTControl, 125 kHz, square housingfa
LF read/write head for IDENTControlfa
LF read/write head for IDENTControlfa
Read/Write head for IDENTControl, 125 kHzfa
Read/Write head for IDENTControl, Europe, Middle East and Africafa
Read/Write head for IDENTControl, Asia and the Americas except Canada, United States and Mexicofa
Read/write head for IDENTControl, USA and Argentinafa
LF read/write head for IDENTControlfa
Accessories

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa

Connection cable, M12 to RJ-45, PUR cable 4-pin, CAT5efa

Connecting cable, M12 to M12, PUR cable 4-pin, shieldedfa

Female cordset, M12, 4-pin, shielded, PUR cablefa

Plug connector for RJ-45fa

MSTB connector, lockablefa
Blind plug for IC-KP-B17-AIDA1fa
Cable, PROFINET, PUR/PE, 4-wire, shieldedfa
Connection cable MSTB to M12 connectorfa
Connection cable MSTB to cable tailfa
Plug connector for RJ-45fa
Connecting cable RJ-45 to M12 D-codedfa
Connecting cable RJ-45 to RJ-45, PUR cable 4-pole, CAT5efa
Visitez le Hub RFID

Visitez notre « Hub RFID » : ce site Internet spécial constitue une base de connaissances du RFID. Obtenez des réponses aux questions fréquemment posées et apprenez les applications RFID types…