Intrinsically safe Ethernet Isolator EI-0D2-10Y-10B

EI-0D2-10Y-10B
  • Galvanic Isolation I.S. to non-I.S. Port
  • 10/100 MBit/s according to IEEE 802.3/.3u
  • Installation in Zone 2, Ethernet in Zone 1 or Zone 0
  • Standard Ethernet patch or crossover cable
  • DIN-Rail mounted and OEM Version

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF:


Caractéristiques techniques  EI-0D2-10Y-10B

Supply
Rated voltage19.2 ... 35 V DC
Rated current150 ... 100 mA
Power dissipation3 W
Ethernet Interface
Intrinsically safe port10 BASE-T/100 BASE-TX
Non-intrinsically safe port10 BASE-T/100 BASE-TX
Connection type2 x RJ-45 , IEC 60603-7
Connector pinoutsocket ; TIA/EIA-568-B
Transfer rate10/100 Mbit/s , Auto-Negotiation
Operating modeHalf/Full Duplex
Cable typeCAT5e S/FTP AWG 24, Installation cable, L/R ratio max. 10 µH/Ω of all strand combinations
I.S. cable lengthtyp. 100 m/20 °C
Total cable lengthtyp. 200 m/20 °C
Number of isolatorsmax. 2 in series connection
Indicators/operating means
LED PWRgreen: Power on
LED ACTyellow: communication active
LED 10/100yellow ON: Transfer rate 100 MBit/s , OFF: 10 MBit/s
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationEN 50020
Degree of protectionIEC 60529
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3 , IEEE 802.3u
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Mechanical specifications
Connection typeTerminals
Core cross-sectionup to 2.5 mm2
Housing materialPolyamide PA 66
Degree of protectionIP20 according to EN 60529
Mass195 g
MountingDIN rail mounting
Data for application in connection with hazardous areas
EU-Type Examination CertificatePTB 07 ATEX 2025 X
MarkingEx-Hexagon II (1) G [Ex ia Ga] IIB ,
Ex-Hexagon II (1) D [Ex ia Da] IIIC ,
Ex-Hexagon II 3(1)G Ex nA [ia Ga] IIB T4 Gc Ex-Hexagon II 3 (1D) G Ex nA [ia IIIC Da] IIB T4 Gc Ex-Hexagon I (M1) [Ex ia Ma] I
Supply
Maximum safe voltage253 V AC
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approvalCSA 15.70016295
Control drawing116-B032
Approved forClass I, Zone 2, AEx/Ex nA [ia Ga] IIB T4 Gc Class I, Zone 2, AEx/Ex nA [ia Da IIIC] IIB T4 Gc
IECEx approvalIECEx PTB 09.0053X
Approved for[Ex ia Ga] IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIB T4 Gc
Ex nA [ia IIIC Da] IIB T4 Gc
[Ex ia Ma] I
Certificates and approvals
PatentsThis product may be covered by the following patent: US7,687,791

Classifications

SystemClasscode
ECLASS 13.027242605
ECLASS 12.027242605
ECLASS 11.027242605
ECLASS 10.0.127242605
ECLASS 9.027242605
ECLASS 8.027242605
ECLASS 5.127242605
ETIM 9.0EC001601
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: EI-0D2-10Y-10B

Informative Literature: EI-0D2-10Y-10B

Language Selection:
LiteratureLangueType de fichierTaille
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB

Product Documentation: EI-0D2-10Y-10B

Language Selection:
Safety and Security DocumentationLangueType de fichierTaille
Manuel d'instructionsFRAPDF68 KB

Design / Simulation: EI-0D2-10Y-10B

Language Selection:
CADLangueType de fichierTaille
CAD 2-D / CAD 2-DALLZIP787 KB
CAD 3-D / CAD 3-DALLSTP2223 KB
CAD Portal / CAD PortalALLLINK---

Approvals: EI-0D2-10Y-10B

Language Selection:
CertificatesIdentificationLangueType de fichierTaille
Canada, USA CSA Certificate of Compliance14.70016295ALLPDF89 KB
Europe PTB ATEX Category 3 ATEX Category (1) GDPTB 07 ATEX 2025XALLPDF2202 KB
PTB IECEx Certificate of ConformityIECEx PTB 09.0053XALLLINK---
Control Drawings
control drawing CSA / Steuerzeichen CSA   ALLPDF94 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1092CALLPDF1041 KB

Ethernet-APL offre une communication continue à tous les niveaux hiérarchiques. En savoir plus sur la technologie pionnière …

Mises à jour RSS Info Service pour PANOS

Soyez informé dès qu'une nouvelle mise à jour logicielle de PANOS, le système d'exploitation des commutateurs Ethernet-APL, est disponible : Grâce à notre flux RSS vous serez immédiatement informé par e-mail de la publication d'une mise à jour.

De la prise de décisions à la planification, en passant par l'installation et la mise en service, sans oublier l'exploitation et la maintenance : Découvrez comment tirer le meilleur parti de votre infrastructure de bus de terrain…