Serviceline Industriële Sensoren
Telefoon +32 3 644 25 00
Serviceline Explosiebeveiliging
Telefoon +32 3 644 25 00

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface KT-MB-GT2AD.FF

KT-MB-GT2AD.FF
  • System integration kit for Advanced Diagnostics
  • PCS integration via Diagnostic Manager or device DTM
  • Simple automatic setup of Advanced Diagnostics
  • Common alarm handling
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Installation in Zone 2

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

De complete datasheet als PDF downloaden:


Technische gegevens  KT-MB-GT2AD.FF

Productbeschrijving
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM
General specifications
Design / MountingMotherboard based
Supply
Rated voltage19.2 ... 35 V DC SELV/PELV
Rated current120 ... 70 mA
Power dissipationmax. 2.5 W
Fieldbus connection
Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 114
ITK version6
Implementationresource block 1x RS
function block 4x MDI, 1x MDO, 1x MAI, 1x DI
transducer block 16x ADM TB, 1x IO TB
Firmware updateEthernet
Polaritypolarity-sensitive
Rated voltage9 ... 35 V SELV/PELV
Rated current0 mA
Ethernet Interface
Port100 BASE-TX
ProtocolTCP/IP and UDP/IP
ServicesICMP , DHCP , AutoIP , HTTP
Connection typeRJ-45 socket, 8-pin
Transfer rate100 MBit/s
Diagnostic Bus
Number of Diagnostic Bus Channels2
Number of Diagnostic Modules/Channel31 Using Ethernet Interface , 8 Using Fieldbus Interface
Terminationintegrated
Cable length/Channel30 m
Indicators/operating means
LED ERRred: Hardware fault
LED PWRgreen: Power on
LINK/ACTyellow
CH1, CH2yellow: diagnostic bus activity
Outputs
Output Ialarm output diagnostic bus channel 1 , volt-free contact , NC contact
Voltage50 V DC
Currentmax. 1 A
Output IIalarm output diagnostic bus channel 2 , volt-free contact , NC contact
Voltage50 V DC
Currentmax. 1 A
Output IIIcommon alarm , volt-free contact , NC contact
Voltage50 V DC
Currentmax. 1 A
Galvanic isolation
All circuits/FEfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output I, II/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 250 Veff
Ethernet/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Ethernet/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Fieldbus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Diagnostic Bus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Standard conformity
Galvanic isolationIEC 62103
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F) hazardous area
-40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Housing materialPolycarbonate
Degree of protectionIP20
Mass470 g
Dimensions
Heightsee dimensions
Widthsee dimensions
Depthsee dimensions
MountingDIN rail mounting
Data for application in connection with hazardous areas
CertificateTÜV 14 ATEX 115980 X
MarkingEx-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx TUN 14.0003X
Approved forEx nA IIC T4 Gc
General information
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.027242692
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027242692
ECLASS 5.127242692
ETIM 9.0EC001604
ETIM 8.0EC001604
ETIM 7.0EC001604
ETIM 6.0EC001604
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: KT-MB-GT2AD.FF

Informative Literature: KT-MB-GT2AD.FF

Taalkeuze:
LiteratureTaalBestandstypeBestandsgrootte
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB
Application Report - Systematic Monitoring of Control CabinetsENGPDF199 KB

Product Documentation: KT-MB-GT2AD.FF

Taalkeuze:
Brief InstructionsTaalBestandstypeBestandsgrootte
Quick Start Guide Diagnostic ManagerENGPDF1520 KB
Safety and Security Documentation
HandleidingHOLPDF225 KB
Manuals
ManualENGPDF25397 KB
Software Information
Release NoteENGPDF284 KB
End-user software license agreement (EULA)ENGPDF37 KB

Approvals: KT-MB-GT2AD.FF

Taalkeuze:
CertificatesCertificaatnummerTaalBestandstypeBestandsgrootte
China SITIIAS CCC Ex Certificate2020322310003538 (Singapore)ALLPDF1423 KB
Europe TUV Nord ATEX Category 3 Zone 2TÜV 14 ATEX 115980 XALLPDF474 KB
TUV Nord Zone 2IECEx TUN 14.0003XALLLINK---
Worldwide Fieldbus FoundationIT082700ALLPDF50 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0596DALLPDF1041 KB

Software: KT-MB-GT2AD.FF

Taalkeuze:
Device Description Files/DriversVrijgave-informatieBestandstypeBestandsgrootte
DD/CFF files HD2-GT-2AD.FF.IO / DD/CFF-Dateien HD2-GT-2AD.FF.IO0102/010102ZIP266 KB
Software Tools
Diagnostic Gateway FF DTM / Diagnostic Gateway FF DTM2.2.3.3527ZIP65378 KB
Pepperl+Fuchs Discovery and Configuration Tool (PFDCT) / Pepperl+Fuchs Discovery and Configuration Tool (PFDCT)2.4.0.412ZIP4773 KB

Aanverwante producten: KT-MB-GT2AD.FF

Matching System Components

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Accessories
Software user interface for Advanced Diagnostic Modules, Simultaneous access to all ADMs of a plant, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PA, Automatic setup of diagnostic systempa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa

Ethernet-APL zorgt voor een ononderbroken gegevensoverdracht over alle hiërarchische niveaus. Leer meer over deze baanbrekende technologie...

RSS-Meldingen voor PANOS-Updates

Ontvang een automatische melding wanneer een nieuwe software-update voor PANOS, het besturingssysteem voor Ethernet-APL-schakelaars, beschikbaar is: Zodra een update wordt vrijgegeven, ontvangt u via onze RSS-feed onmiddellijk een e-mailbericht in uw inbox.

Van beslissing over planning, installatie en indienstname tot gebruik en onderhoud: Ontdek hoe u het beste uit uw veldbusinfrastructuur kunt halen…