Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Detection range directly adjustable without removing front panel, Accurate beam alignment thanks to finely bundled light beam, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Background suppression operating mode: ignores objects outside the sensing range, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 30 V DC, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collectorfa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Background suppression operating mode: ignores objects outside the sensing range, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Background suppression operating mode: ignores objects outside the sensing range, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: fixed cable high flexibility 2.5 mfa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Accurate beam alignment thanks to finely bundled light beam, Background evaluation operating mode: uses the background as a reference for detecting difficult objects, Version with pre-assembled flush-mounted installation frame, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Accurate beam alignment thanks to finely bundled light beam, Detection range directly adjustable without removing front panel, Version with pre-assembled flush-mounted installation frame, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Background evaluation operating mode: uses the background as a reference for detecting difficult objects, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 30 V DC, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collectorfa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Background evaluation operating mode: uses the background as a reference for detecting difficult objects, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 48 V DC / 11 ... 36 V AC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Flush-mounted version with front cover, black, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 10 ... 30 V DC, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collector, Connection: 2 m fixed cablefa
Single-beam light scanner, Can be used to monitor both main and ancillary closing edges, Closing edge safety on revolving doors and carousel doors, Accurate beam alignment thanks to finely bundled light beam, Flush-mounted version with front cover, black, Function: Secure, Sensor principle: Active infrared scanner, Operating voltage: 24 V DC, Signal output: 1 PNP output, short-circuit protected, reverse polarity protected, open collectorfa
Portas automáticas, elevadores, escadas rolantes, barreiras ou transporte público: os sensores do portfólio da Pepperl+Fuchs são adequados para uma ampla variedade de aplicações na automação de acesso ... de porta. Monitoramento da borda principal e da borda articulada O leitor de infravermelho ativo AIR30 é usado para monitorar as bordas principal e articulada das portas de ônibus e de trens. Devido ao seu feixe de luz precisamente focado, o sensor permite ...
1-1/1Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.