Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and bluefa
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
Photoelectric slot sensor, zinc pressure diecast housing, 80 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red lightfa
1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line fault detection (LFD) for Pt100, Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the control system, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Signal: Resistancepa
1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the control system, HART communication, Safety Integrity Level (SIL): SIL 3, Rated voltage: 0 ... 24 V DC , loop powered, Signal: 1 x 1 ... 20 mA, Signal [2]: 1 x HART, Device: 1 x fire alarm, Signal: 1 x 1 ... 20 mApa
1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, 2 relay contact outputs, Adjustable energized/de-energized delay, Programmable high/low alarm, Linearization function (max 20 points), Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, HART communication, Trip relay, Safety Integrity Level (SIL): SIL 2pa
1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 Ω load, HART-IP and valve positioner, Line fault detection (LFD), Accuracy 0.1 %, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the field, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Signal: 2 x 4 ... 20 mA, Line fault detectionpa
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x Transistor (passive)pa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Indisponível para compra: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Indisponível para compra: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Indisponível para compra: 1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 65 mA at 9.8 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≤ 65 mA, Voltage: ≥ 9.8 Vpa
Indisponível para compra: 2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: ≤ 45 mA, Voltage: ≥ 11.7 Vpa
Pepperl+Fuchs' PXV absolute positioning system sets new benchmarks for reliability, noise immunity, and handling Discover the most reliable positioning system on the market ... the exact position in relation to the camera's center. Using Data Matrix codes as information carriers allows data to be redundantly mapped . Due to these multiple redundancies, the PXV is extremely resistant to interference. Even if one or more Data ...
Pepperl+Fuchs offers the inductive positioning systems PMI F90 and PMI F112 that feature comprehensive functions, paving the way for modern industry 40 applications ... information . High flexibility. Broad functionality. Diverse applications. Inductive positioning systems operate contact-free using an inductive sensor and a damping element . There is no need for a special target —a steel target or a machine part itself can ...
There are four types of ultrasonic sensors, operating in different ways Read more about diffuse mode sensors, retroreflective sensors, thru-beam sensors and double sheet sensors here ... Operating Modes Determining the distance to an object using the echo transit time method can be evaluated and displayed in different ways. Besides, the height of the echo amplitude can be used for evaluation purposes. In general, a distinction can ...
Ver Todos: As estações de I/O remoto LB são montadas em áreas classificadas Zona 2, Classe I/Div 2 ... actuators to the DCS using a single standardized fieldbus connection (PROFIBUS, Modbus, etc.). A wide range of single- and multi-channel I/O modules is available—ensuring that engineering is easy and adaptable to the needs of your plant concept. Universal ...
Pepperl+Fuchs has industrial sensors for customized or standard solutions for digital printing and ATM machines ... . For consistent front and lateral alignment photoelectric background suppression sensors precisely detect sheets and edges. RFID technology reliably identifies consumables by tracking and tracing. Ink substances are also detected through toner cartridges using ...
Pepperl+Fuchs offers a wide variety of industrial sensors for sheet fed printing applications ... Enhanced edge detection using background suppression sensors Fast response time Cylinder and Part Position Sensor Solution: Inductive sensors, encoders Customer Benefits: Precise detection of metal gear teeth, notches, and cams Reduction factor 1 senses ...
Ver Todos: São ideais para praticamente qualquer tipo de aplicação Versões macho e fêmea com conexões M8, M12, 1/2" e 7/8" em modelos de 3, 4 e 5 pinos atendem aos requisitos de qualquer tipo de inst ... usinado possibilita um grau de proteção IP67. ...
Ver Todos: A Pepperl+Fuchs fornece uma variedade de cabos e conectores Encontre a solução ideal para a sua aplicação! ... de qualquer tipo de instalação. O invólucro de alumínio usinado possibilita um grau de proteção IP67. Conectores de Dados Nosso amplo portfólio abrange praticamente qualquer tipo de interface industrial, desde Ethernet, DeviceNet, PROFIBUS, CANopen e INTERBUS até USB e RS-232 ...
The automotive industry effectively uses RFID technology along the assembly line ... . Additionally, these data will be used for quality control purposes. Because the parts identification using RFID is fully automatic, manual processes using mobile barcode readers can be omitted. The Pepperl+Fuchs IDENT Control solution offers an RFID operating ...
The new FieldConnex® fieldbus diagnostic handheld device (FDH-1) from Pepperl+Fuchs greatly simplifies fieldbus installation ... handling represents a real advantage and no special knowledge is required . As a stand-alone solution, no PC is needed . Instead, the device can be easily connected to any fieldbus segment . Testing begins using "single-click operation." Integrated expert ...
61-70/77Itens por Página:
Não encontrou nenhum resultado?
Dica: Digite o caractere * antes do termo a ser pesquisado, modifique sua pesquisa, verifique os termos ou entre em contato conosco.