General specifications |
Signal type | Analog output |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 2 |
Supply |
Connection | Power Rail or terminals 7+, 8- |
Rated voltage | 20 ... 35 V DC |
Ripple | within the supply tolerance |
Rated current | max. 50 mA |
Power dissipation | 1.4 W |
Input |
Connection side | control side |
Connection | terminals 9+, 10-, 11+ |
Voltage drop | approx. 4 V at 20 mA |
Input current | ≤ 100 µA up to 50 °C (122 °F) at 10 V |
Limit | max. 40 mA |
Transmission range | 0 ... 20 mA |
Output |
Connection side | field side |
Connection | terminals 1+, 2- |
Voltage | 17 V at 20 mA |
Current | 0 ... 20 mA |
Load | output resistance: max. 3 Ω |
Transfer characteristics |
Deviation | at 20 °C (68 °F), 4 ... 20 mA < 0.1 % of full scale, incl. non-linearity and hysteresis |
| Influence of ambient temperature | ≤ ± 0.01 %/K |
Rise time | < 10 ms |
Galvanic isolation |
Input/power supply | functional insulation, rated insulation voltage 50 V AC |
Indicators/settings |
Display elements | LED |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Degree of protection | IEC 60529:2001 |
Protection against electrical shock | UL 61010-1:2012 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Connection | screw terminals |
Mass | approx. 100 g |
Dimensions | 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1 |
| Height | 107 mm |
| Width | 20 mm |
| Depth | 115 mm |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas |
EU-type examination certificate | BAS 02 ATEX 7203 X |
| Marking | II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I |
Certificate | TÜV 99 ATEX 1499 X |
| Marking | II 3G Ex nA II T4 |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals |
FM approval | |
| Control drawing | 116-0440 |
UL approval | |
| Control drawing | 116-0441 (cULus) |
IECEx approval | |
| IECEx certificate | IECEx BAS 05.0041X IECEx CML 19.0051X |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc |
General information |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |