Serviceline Industrial Sensors
Serviceline Explosion Protection

Diagnostic Manager Software DTM-FC.AD*

DTM-FC.AD*
  • Software user interface for Advanced Diagnostic Modules
  • Simultaneous access to all ADMs of a plant
  • Embedded expert system gives pointed advice in clear text
  • Includes Commissioning Wizard, data historian, oscilloscope...
  • For FOUNDATION Fieldbus H1 and PROFIBUS PA
  • Automatic setup of diagnostic system

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

下载PDF版完整参数表:


技术参数节选  DTM-FC.AD*

产品阐述
User-Interface for Advanced Diagnostics, Professional Edition
Software
Hardware requirementsPC with 1 GHz processor and at least 512 MByte RAM
Operating systemsee release notes in the software package
LanguagesEnglish
LicensingNew plant licenses:
DTM-FC-AD for production process plants with up to 100 segments
DTM-FC-AD.1 for more than 100 segments
Upgrade licenses:
DTM-FC-AD.UPG upgrade of existing DTM-FC-AD
DTM-FC-AD.1.UPG upgrade of existing DTM-FC-AD.1
Expert SystemBuilt-in expert system interprets behavior of each segment based on rules and gives pointed information in clear text. Precisely diagnosis causes and suggests remedies, which are easy to understand.
Physical Layer DiagnosticsBulk power health, segment voltage and current, unbalance, noise, signal level, signal polarity, jitter
Commissioning WizardGenerates reports on physical layer and communications data per device or segment. Automates repetitive tasks during commissioning.
Snapshot ExplorerUser interface to review the history of Physical Layer Measurement Reports stored.
History Data ExportExport of long-term history data to Excel and the file formats comma-separated (CSV) or binary for graphic analysis and diagram creation
Segment Focus ModeFast update of detailed measurements for a single segment
Integrated oscilloscopeDisplays fieldbus signals in waveform giving greatest detail. To aid troubleshooting activities, even seldom occuring events can be captured using the oscilloscope's many selectable trigger functions.
OPC Server InterfaceThe open OPC server interface can easily be adapted to any OPC client. It provides as a Data Access Server (Version 2.05) Summarized State information and basic diagnostic data such as the operating status of the diagnostic module and of the segments.
Remote diagnosticsFieldbus experts and maintenance contractors are enabled to review Physical Layer diagnostics from off-site.

Classifications

SystemClasscode
ECLASS 13.027242505
ECLASS 12.027242502
ECLASS 11.027242502
ECLASS 10.0.127242502
ECLASS 9.027242502
ECLASS 8.027242502
ECLASS 5.127242502
ETIM 9.0EC000757
ETIM 8.0EC001416
ETIM 7.0EC001416
ETIM 6.0EC001416
ETIM 5.0EC000809
UNSPSC 12.143232901
Product category / 产品类的

Details: DTM-FC.AD*

Product Documentation: DTM-FC.AD*

选择语言:
Product information语言文件类型文件大小
Technical Information Advanced Diagnostic with Yokogawa Plant Resource Manager (PRM)ENGPDF2551 KB
Brief Instructions
Quick Start Guide Diagnostic ManagerENGPDF1520 KB
Manuals
ManualENGPDF25397 KB
Software Information
Release NoteENGPDF284 KB
End-user software license agreement (EULA)ENGPDF37 KB

Software: DTM-FC.AD*

选择语言:
Software ToolsRelease Info文件类型文件大小
Diagnostic Gateway FF DTM / Diagnostic Gateway FF DTM2.2.3.3527ZIP65378 KB
Diagnostic Manager / Diagnostic Manager2.2.4.3610ZIP87499 KB
Pepperl+Fuchs Discovery and Configuration Tool (PFDCT) / Pepperl+Fuchs Discovery and Configuration Tool (PFDCT)2.4.0.412ZIP4773 KB

配套产品: DTM-FC.AD*

Accessory of

Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Comprehensive diagnostics for the fieldbus physical layer, Module and motherboard for retrofit of any installation, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, USA, Canada, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europepa
System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Alarm handling and integrated I/O for cabinet monitoring/control, For FOUNDATION Fieldbus and PROFIBUS PA, International, Europe, Device coupler location: non-explosion hazardous area
Zone 2 - high-power trunk
Zone 1 - high-power trunk
Division 2 - high-power trunk
Division 1 - high-power trunkpa
Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa