Servisní linka pro průmyslové snímače
Servisní linka ochrany před výbuchem

Safety thru-beam sensor SLA29/73c

SLA29/73c
  • Sensing range up to 30 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Integrated alignment aid
  • Clearly visible LED functional display and pre-fault indicator on the receiver
  • Sturdy housing
  • Waterproof, degree of protection IP67
  • Operation on SB4-series control units (SafeBox)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Stáhněte si kompletní katalogový list ve formátu PDF:


Výňatek z katalogového listu: Technická data   SLA29/73c

System components
EmitterSLA29-T/73c
ReceiverSLA29-R/73c
General specifications
Effective detection range0.2 ... 30 m
Threshold detection range40 m
Light sourceLED
Light typemodulated visible red light
Target sizestatic: 30 mm
dynamic: 40 mm (at v = 1.6 m/s of the obstacle)
Alignment aidLED red in receiver
Angle of divergence< 5 °
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd4.4 E-10
Type4
Indicators/operating means
Operation indicatorLED green
Function indicatorLED yellow:
1. LED lit constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Electrical specifications
Operating voltagePower supply via control unit
Conformity
Functional safetyISO 13849-1
Product standardEN 61496-1 ; IEC 61496-2
Approvals and certificates
CE conformityCE
CCC approvalCCC approval / marking not required for products rated ≤36 V
ApprovalsTÜV
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 70 °C (-4 ... 158 °F)
Relative humiditymax. 95 %, not condensing
Mechanical specifications
Degree of protectionIP67 according to EN 60529
ConnectionM12 connector, 4-pin
Material
HousingABS plastic, RLA 1021 (yellow) painted
Optical facePlastic pane
Massper device 70 g

Documents: SLA29/73c

Instruction leafletsJazykTyp souboruVelikost souboru
Instruction leaflet / Beipackzettel ALLPDF293 KB

Approvals+Certificates: SLA29/73c

Statements of complianceČíslo certifikátuTyp souboruVelikost souboru
EU-Declaration of conformity / EU-KonformitätserklärungDOC-2144BPDF163 KB
Certificates
/cert/cert1312c.pdfZ10 17 12 20068 079PDF366 KB
E215245LINK---

Software: SLA29/73c

Software ToolsInformace o uvolněníTyp souboruVelikost souboru
SISTEMA Library Sensors / SISTEMA-Bibliothek SensorenZIP131 KB

Související produkty: SLA29/73c

Matching System Components
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 8 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Accessories
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Mounting bracket fa
Mounting bracket fa
Muting setfa
Muting setfa
Deflecting mirror for single-beam deflection of the protection beam of safety light beams in the SL and SLA seriesfa
Centrum funkční bezpečnosti od společnosti Pepperl+Fuchs

Stovky produktů s vyhodnocením SIL/PL, bezplatné nástroje a brožury na jednom místě: centrum funkční bezpečnosti je vaším výchozím bodem, když potřebujete implementovat bezpečnostní funkce.