Support Industrielle sensorer
Support Explosion Protection

Mounting aid Safety MS SLP/SLA28

MS SLP/SLA28
  • Muting set

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   MS SLP/SLA28

Produkt beskrivelse
Fixing plate
Mechanical specifications
MaterialMetal sheet (steel), powder coated yellow
Suitable series
Safety SeriesSLP

Tilhørende produkter: MS SLP/SLA28

Accessory of
Sensing range 8 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range 8 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 3-radial design, Beam spacing 400 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 3-radial design, Beam spacing 400 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 3-radial design, Beam spacing 400 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 3-radial design, Beam spacing 400 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 4-radial design, Beam spacing 300 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 4-radial design, Beam spacing 300 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 4-radial design, Beam spacing 300 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 4-radial design, Beam spacing 300 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range 8 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Connection: M16 cable gland ,
terminal compartmentfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Extended temperature range up to -35 °C with heated front panel, Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Connection: M12 connector, 5 pinfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on SB4-series control units (SafeBox), Construction type(S2): Rectangular type, Connection: M12 connector, 4-pinfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Connection: M12 connector, 4-pinfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Connection: terminal compartmentfa
Sensing range up to 65 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Sturdy housing, Waterproof, degree of protection IP67, Operation on control units of SB4 (SafeBox), Construction type(S2): Rectangular type, Connection: terminal compartmentfa
Sensing range up to 30 m, Self-monitoring (type 4 according to IEC/EN 61496-1), Extended temperature range up to -35 °C with heated front panel, Red transmission light, Integrated alignment aid, Clearly visible LED functional display and pre-fault indicator on the receiver, Operation of control units of Series SB4, Construction type(S2): Rectangular type, Connection: M12 connector, 5 pinfa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.