SLP8-2-A-L
  • Sensing range 8 m
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • 2-radial design
  • Beam spacing 500 mm
  • Red transmission light
  • Integrated function display
  • Pre-fault indication
  • Operation on control units of SB4 (SafeBox)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   SLP8-2-A-L

Produkt beskrivelse
Safety light grid, active column
System components
TransceiverSLP8-2-A
Mirror pillarSLP8-2-M
General specifications
Effective detection range0.2 ... 8 m
Light sourceLED
Light typemodulated visible red light
TestsIEC/EN 61496
Safety type according to IEC/EN 614964
MarkingCE
Target sizestatic: 32 mm
dynamic: 50 mm (at v = 1.6 m/s of the obstacle)
Beam spacing500 mm
Number of beams2
Angle of divergence< 5 °
Functional safety related parameters
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFHd2.81 E-9
Type4
Indicators/operating means
Operation indicatorLED red in transceiver
Function indicatorLED red: per receiver channel
off: Interruption
flashes: receiver
continuously on: reception with sufficient stability control
Muting indicatorIndicator lamp
Pre-fault indicatorFunctional display flashing
Electrical specifications
Operating voltagePower supply via control unit
Protection classIII , IEC 61140
Conformity
Functional safetyISO 13849-1
Product standardEN 61496-1 ; IEC 61496-2
Approvals and certificates
CE conformityCE
CCC approvalCCC approval / marking not required for products rated ≤36 V
ApprovalsTÜV
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 70 °C (-4 ... 158 °F)
Relative humiditymax. 95 %, not condensing
Mechanical specifications
Degree of protectionIP65
ConnectionM16 cable gland ,
terminal compartment
Connection optionsFurther electrical connection options on request:
Connector DIN 43 651 Hirschmann, emitter: 6-pin+PE, receiver: 11-pin+PE
Material
Housingextruded aluminum profile, RAL 1021 (yellow) coated
Optical facePlastic pane
MassPer 2100 g

Documents: SLP8-2-A-L

Instruction manualsSprogFil typeFil størrelse
Manual SLP Safety light gridENGPDF600 KB
Handbuch Sicherheitslichtgitter SLPGERPDF597 KB

Approvals+Certificates: SLP8-2-A-L

Statements of complianceCertifikat nr.Fil typeFil størrelse
EU-Declaration of conformity / EU-KonformitätserklärungDOC-2147APDF164 KB
Certificates
/cert/cert1314d.pdfZ10 020068 0084PDF75 KB
/cert/cert1511b.pdfU8V 020068 0085PDF205 KB
E215245LINK---

Software: SLP8-2-A-L

Software ToolsUdgivelses infoFil typeFil størrelse
Software tools / Software ToolsZIP131 KB

Tilhørende produkter: SLP8-2-A-L

Matching system components
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, Expansion slots for SB4 modules for optional enhanced functionality, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, 7-segment diagnostic display, Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Evaluation unit for security through-beam sensors SLA5(S) and SLA40; for safety light grids SLP, for safety light curtains SLC; for switching pads and emergency stop buttons of categories 2 and 4, 8 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Operating voltage: 24 V DC, ± 20 %fa
Accessories
Deflecting mirror for multi-sided protection safety layouts using SLP series safety light gridsfa
Mounting bracket for Light gridfa
Glass panel to protect the light outlet surface of safety light grids and curtainsfa
Bracket for mounting the glass panel for the protection of the light outlet surface of safety light grids and curtainsfa
Simplified alignment of the SLC and SLP profile light grids fa
Floor stand for all series SLP/SLC devicesfa
Floor stand for all series SLP/SLC devicesfa
Shock absorber as ramming protector for all series SLP/SLC devicesfa
Housing for floor standfa
Muting setfa
Cable tie for the secure laying and fixing of the connection leads, in particular for the muting sensors connected to safety light grids.fa
Deflecting mirror for single-beam deflection of the protection beam of safety light beamsfa
Functional Safety Hub from Pepperl+Fuchs