Select Your Country

Go to global website

Archived Product Version

VBA-2E-KE4-ENC-S AS-Interface safety module

Key Benefits at a Glance

  • SIL3 (EN 62061)
  • Addressing jack
  • Memory card for configuration data
Product Compliance: Europe – CE
Product Compliance: USA - cULus
AS-Interface® interface
Note

All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

EN
  • DE
  • EN
  • FR

Technical data of VBA-2E-KE4-ENC-S

KE4 control cabinet module
2 inputs for incremental rotary encoders
Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V3.0
UL File NumberE223772
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
Mission Time (TM)20 a
PFHd2.77 E-9
LED FAULTerror display; LED red
red: communication error
LED AS-iAS-Interface voltage; LED green
LED AUXext. auxiliary voltage UAUX ; LED green
LED CONFOff = Normal mode, yellow LED
LED STATEStatus of rotary encoder, 2 yellow LEDs
LED FREQUENCYLow frequency or halt, 2 LED yellow
Auxiliary voltage (input)UEXT18 … 30 VDC
Insulation voltageUi500 V AS-Interface/UAUX:
Rated operating voltageUe18,0 ... 31.6 V from AS-Interface
Rated operating currentIe≤ 150 mA from AS-Interface;
≤ 200 mA from AUX
Interface typeChip card slot
Number/Type2 inputs for incremental rotary encoders
AMP mini-IO connector
VoltageUb = 5 V DC
Signal delay100 ms at 1015 Hz < flimit
140 ms at 45 Hz < flimit < 1015 Hz
700 ms at flimit < 45 Hz
Signal frequencyParameterization range 25 Hz … 200 kHz
Current≤ 100 mA
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Degree of protectionEN 60529:2000
Electrical safetyEN 954-1:1996 (up to Kategorie 4), EN 62061:2005 (up to SIL3) EN ISO 13849-1:2006 to PL e
InputEN 61131-2:2007
AS-InterfaceEN 62026-2:2013
ProfileSafe input slaves: S-0.B.E
Diagnosis slaves: S-7.A.5.
IO code0
ID codeB
ID1 codeF
Ambient temperature0 ... 55 °C (32 ... 131 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Degree of protectionIP20
Connectionremovable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material
HousingPA 66-FR
Dimensions
Height99 mm
Width22.5 mm
Length113 mm
MountingDIN mounting rail