Industrial standard housing ∅58 mm, Up to 50,000 ppr, Hollow shaft, 10 V ... 30 V with short-circuit proof push-pull output, Output type: push-pull, incrementalfa
Industrial standard housing ∅58 mm, Up to 50,000 ppr, Hollow shaft, 10 V ... 30 V with RS 422 interface, Up to 5000 ppr, Output type: RS 422, incrementalfa
Compact design housing ∅90 mm, Variable hollow shaft from ∅16 mm ... ∅45 mm, Up to 50,000 ppr, Easy shaft clamping, Very high resolution and accuracy, Enclosure type: 90 mm, Type of shaft: Hollow shaft, Interface: RS-422, Detection type: photoelectric sampling, Output type: push-pull, incremental or RS-422, incremental (see "Output circuit" in the ordering information)fa
Incremental encoder with sin/cos interface, 1024 or 2048 signal periods, Industrial standard housing ∅58 mm, Hollow shaft up to 15 mm, Temperature compensated, interpolateable voltage signals, Output type: sine / cosinefa
Remote Monitor - System with enclosure, Designed for use in the extended temperature range of -20 °C ... 50 °C with rugged aluminum housing, Thin Client solution (with VisuNet RM Shell firmware), Suitable for outdoor use with various sunshield options, Fully modular design allowing easy migration of individual
components, High application flexibility due to identical basic components that can be can be configured as requiredpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: Switching function: Normally open/closed (NO/NC) programmable, Output type: AS-Interface, Installation: non-flush, Output type: 2-wire, Construction type: VariKont L®, Series: VariKont L®, Operating voltage: 26.5 ... 31.9 V via AS-i bus system, Type of voltage: DC, Connection type: Connector plug M12 x 1 , 4-pin, Housing material: PA, Degree of protection: IP67fa
Not available for purchase: Diffuse sensor with measurement core technology, large housing design, background suppression and 3 more adjustable operating modes, IO-Link interface, 800 mm adjustable detection range, red light, 2 push-pull outputs, fixed cable, Cost-optimized series for standard tasks, Sensing-by-ranging functionality, IO-Link interface for service and process data, PowerBeam transmitter LED, Large adjustment range can be precisely definedfa
Not available for purchase: Resistant to salt water, Industrial standard housing ∅58 mm, 1024 ppr, Recessed hollow shaft, 10 V ... 30 V with short-circuit proof push-pull output, Output type: push-pull, incrementalfa
The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas Learn more about the USi-safety ultrasonic sensor system ... USi-safety Ultrasonic Sensor System USi-safety Benefits Technology System Applications Experts Contact Us Safety without exception. Conquering the elements with unique ultrasonic technology for maximum safety. The USi®-safety Sensor System in ...
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area ... correspondingly large automated guided vehicles (AGV). Additionally, the routes are used by other vehicles, and also by people, either on foot or riding bicycles. The AGV is controlled using an electronic connection to a tag track . However, long tanks require a ...
A through-beam sensor with a large aperture angle enables robust signal transmission and thus allows the AMRs to reliably transfer material to transfer stations ... Solution BB10-P-F1/BB10-P-F2 series The BB10-P-F1/BB10-P-F2 series of thru-beam sensors provide the ideal complete package. By using two thru-beam sensors , simple two-bit signal transmission can be established to trigger loading or unloading at the ...
AGVs used in automated production lines need to be positioned accurately The safePGV positioning system enables reliable absolute positioning in accordance with SIL 3/PL e using just one sensor ... or PL e and be designed to be correspondingly robust. The Solution safePGV Positioning System The safePGV positioning system allows for reliable absolute positioning in accordance with SIL 3/PL e using just one sensor . The new safety technology ...
Precise alignment of heliostats in solar tower power plants using rotary encoders and tilt sensors Sensors that detect positions along two axes ... Precise alignment of heliostats in solar tower power plants using rotary encoders and tilt sensors Sensors that detect positions along two axes ... ...