Analog position indicator with end position monitoring, 2 configurable switching frames, Preset range of angle measurement 0 ... 90°, Extended analog signal range, Measurement range: max. 180° min. 90°, Operating voltage: 18 ... 30 V DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable, Output type: current output 3.8 ... 20.5 mA (RL < 400 Ω), UL approval: cULus Listed, General Purpose, Class 2 Power Sourcefa
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scaleable measurement range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: fixed cable with plug, Housing: Zinc diecast, nickel-plated cover , PBT, Threading: M12 x 1fa
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 960 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M12 connector, Housing material: PA 6 / AL, Degree of protection: IP65, Housing: PA 6 / ALfa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmablefa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 14 mm, Analog output 0 ... 10 V, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: Push-pull (4 in 1) output , short-circuit protected, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, Connection type: M8 connector, 4-pin, Housing material: PA 6, Degree of protection: IP67fa
Not available for purchase: Parameterization and diagnosis via IO-Link, Measuring range 0 ... 14 mm, Analog output 0 V ... 5 V, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 5 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector, 4-pin, Housing material: PA 66, Degree of protection: IP67fa
Not available for purchase: Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scaleable measurement range programmable via cable, 5 scaling positions progammable using teach in device PMI14V-Teach, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: 1 m, PUR cable, shielded, Housing: Zinc diecast, nickel-plated cover , PBTfa
Not available for purchase: Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Option of parameterizing signaling zone, position and width, Output polarity: DC, Measurement range: 360°, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed, General Purpose Class 2 power source, Connection type: 5-pin, M12 x 1 connector, Housing material: PBT, Degree of protection: IP67fa
Not available for purchase: Position sensor for PAX001, Measuring range 0 ... 360°, RS 232 transmission, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: RS 232, for communication with interface box PAX..., UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 5-pin, M12 x 1 connector, Housing material: PBT, Degree of protection: IP67fa
Not available for purchase: Measuring range 0 ... 360°, Adjustable switch points, Analog output 0 ... 10 V, Output polarity: DC, Measurement range: 360°, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose Class 2 power source, Connection type: 5-pin, M12 x 1 connector, Housing material: PBT, Degree of protection: IP67fa
Not available for purchase: Analog output, load-dependent voltage or current, 2 configurable switching frames, Parameterisable measuring range, Measurement range: max. 360° min. 90°, Operating voltage: 18 ... 30 V DC, Output type: 2 switch outputs NPN, NO , reverse polarity protected , short-circuit protected , programmable, Output type: current output or voltage output (load dependend) 4 ... 20 mA (RL < 400 Ω) 0 ... 10 V (RL > 3.3 kΩ)fa