UBC250-12GM-I-V1
Tuotekuvaus |
Single head system |
General specifications |
Sensing range | 30 ... 250 mm |
Adjustment range | 50 ... 250 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 310 kHz |
Response delay | approx. 50 ms |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
No-load supply current | ≤ 30 mA |
Input |
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
Output |
Output type | 1 analog output 4 ... 20 mA |
Resolution | 0.17 mm
|
Deviation of the characteristic curve | ± 1 % of full-scale value |
Repeat accuracy | ± 0.5 % of full-scale value |
Load impedance | 0 ... 300 Ω at UB > 10 V; 0 ... 500 Ω at UB > 15 V |
Temperature influence | ± 1.5 % of full-scale value |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
Approvals and certificates |
UL approval | cULus Listed, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 4-pin |
Degree of protection | IP68 / IP69K |
Material | |
| Housing | Stainless steel 1.4404 / AISI 316L O-ring for cover seal: Viton |
| Transducer | PTFE (diaphragm surface) |
Mass | 35 g |
Dimensions | |
| Length | 70 mm |
| Diameter | 12 mm |
Factory settings |
Output | evaluation limit A1: 50 mm evaluation limit A2: 250 mm output function: rising ramp |
Classifications
System | Classcode |
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Details:
UBC250-12GM-I-V1
Product Documentation:
UBC250-12GM-I-V1
Design / Simulation:
UBC250-12GM-I-V1
Approvals:
UBC250-12GM-I-V1
Liitännäistuotteet:
UBC250-12GM-I-V1
Accessories |
|
|
|
Programming unitfa |
|
|
|
|
Ultrasonic -deflector, Universal mounting possibilities, 90° sound deflection for difficult installation circumstancesfa |
|
|
|
|
Single-ended female cordset, M12, V4A stainless steel, hygienic design, 4-pin, PP cablefa |
|
|
|
|
Single-ended female cordset, M12, V4A stainless steel, hygienic design, 4-pin, PP cablefa |
|
|
|
|
Mounting aidfa |
|