Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Lataa koko tietolomake PDF-tiedostona:
General specifications | ||
---|---|---|
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-G6*-O4 and a signal converter S1SD-1TI-1U. | |
Series | LMC-P | |
Versions | LMC10P6-G6P-O4 LMC10D5-G6D-O4 |
|
Output | ||
Connection | 3-wire, potentiometer connection approx. 40 kΩ | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity | ||
Degree of protection | IEC 60529:2000 | |
Measurement accuracy | ||
Accuracy | resolution: 10 mm | |
Operating conditions | ||
Process conditions | ||
Process temperature | version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) |
|
Process pressure (static pressure) | ≤ 3 bar (43.5 psi) | |
Density | ≥ 0.8 g/cm3 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP66 / IP68 | |
Connection | terminal box, 3 terminals , max. 2.5 mm2 | |
Material | float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) terminal box: Polyester |
|
Dimensions | float: - version PP: cylinder ∅55 mm x 54 mm - version PVDF: cylinder ∅55 mm x 70 mm guide tube: ∅14 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm |
|
Process connection | thread G2A to DIN/ISO 228/1 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Designation | - LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF - LML-FP6 float, cylinder, Ø55 mm x 54 mm, PP |
System | Classcode |
---|---|
ECLASS 13.0 | 27200502 |
ECLASS 12.0 | 27200502 |
ECLASS 11.0 | 27200502 |
ECLASS 10.0.1 | 27200502 |
ECLASS 9.0 | 27200502 |
ECLASS 8.0 | 27200502 |
ECLASS 5.1 | 27200502 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC001447 |
ETIM 7.0 | EC001447 |
ETIM 6.0 | EC001447 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
The device is a sensor for continuous level measurement in liquids.
A ring magnet integrated in the float activates a reed contact resistance chain inside the probe tube via its magnetic field.
If the level changes, the resistance chain changes its total resistance by closing the contact at the float level. The resistance is converted into a standardised output signal by a control unit. This output signal is proportional to the level of the measured medium.
Safety and Security Documentation | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Käyttöohje | FIN | 0 KB | |
Manuals | |||
Manual LMC-** | ENG | 835 KB |
Declaration of Conformity | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2635 | ALL | 64 KB | |
Contamination Declaration | ||||
Contamination declaration / Kontaminationserklärung | ALL | 137 KB |