Single head system, Analog output 4 mA ... 20 mA, Extremely small unusable area, TEACH-IN, Series: -F42, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 ... 20 mA, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABSfa
Single head system, Switching output, 5 different output functions can be set, Program input, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E5, PNP, NO/NC, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: ABSfa
Not available for purchase: Single head system, Separate evaluation, With temperature sensor, Direct detection mode, Series: VariKont®, Operating voltage: 20 ... 30 V DC , ripple 10 %SS, Output type: 1 pulse output for temperature 1-level: > 4 V (100 µA), 0-level: < 0.5 V (100 µA) 1 pulse output for echo propagation time 1-level: ≥ UB -3 V (< 10 mA), 0-level: ≤ 1 V (100 µA), UL approval: cULus Listed, General Purposefa
Not available for purchase: Single head system, Serial digital output, 3 different output options can be programmed, Paramaterization input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 serial output, push/pull, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Not available for purchase: Single head system, 2 switch outputs, 3 different output functions can be set, Selectable sound lobe width, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 2 switch outputs PNP, NO/NC, programmable, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Not available for purchase: Single head system, Frequency output, 3 different output options can be programmed, Paramaterization input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 frequency output, push/pull, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Not available for purchase: Single head system, PWM output, 3 different output options can be programmed, Paramaterization input, Series: -18GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 PWM output, push/pull, programmable, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-platedfa
Not available for purchase: Single head system, Switch output, 5 different output functions can be set, Program input, Series: -30GM, Operating voltage: 20 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E0/E1, NPN, normally open/closed, programmable, Connection: 5-pin V15 (M12 x 1) connector, Housing: nickel plated brass; plastic components: PBTfa
Not available for purchase: Single head system, Switch output, 5 different output functions can be set, Program input, Series: -30GM, Operating voltage: 20 ... 30 V DC , ripple 10 %SS, Output type: 1 switch output E2/E3, PNP, NO/NC, programmable, Connection: 5-pin V15 (M12 x 1) connector, Housing: nickel plated brass; plastic components: PBTfa
Not available for purchase: Single head system, Separate evaluation, Direct detection mode, Series: -30GM, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 pulse output for echo propagation time, high-active, short-circuit proof, UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, Connection: 2 m PVC cable 0.75 mm2, Housing: nickel plated brass; plastic components: PBTfa
Not available for purchase: Single head system, Separate evaluation, Direct detection mode, Series: -F54, Operating voltage: 10 ... 30 V DC , ripple 10 %SS, Output type: 1 pulse output for echo run time, short-circuit proof open collector PNP with pulldown resistor = 22 kOhm level 0 (no echo): -UB level 1 (echo detected): ≥ (+UB-2 V), UL approval: cULus Listed, General Purpose, CSA approval: cCSAus Listed, General Purpose, Connection type: Connector plug M12 x 1 , 4-pinfa
Stack turners and stack handling equipment use a variety of industrial sensors from Pepperl+Fuchs ... angle in one or two axes Angular resolution 0.1° Both analog and switching outputs Two adjustable switching points Distance Measurement Devices Sensor Solution: UB500-18GM, UB500-F54, UC500-L2, VDM28 Customer Benefits: Precise detection of position ...
Web fed printing applications are solved with ultrasonic sensors or photoelectric sensors from Pepperl+Fuchs ... Photoelectric and ultrasonic solutions Web Tensioning Sensor Solution: Distance measurement VDM28, UB500-F54 Customer Benefits: Ensures consistent web tension Consistent end of roll/splice detection Unaffected by paper dust Versatile mounting Solutions include ...
Industrial sensors from Pepperl+Fuchs are used on die cutting machinery ... immunity to interference from reflective surfaces SafeBox modular safety controller connects all safety components into one unit Pallet Detection Sensor Solution: Distance measurement devices UB500-18GM, UB500-F54, UC500-L2, VDM28 Customer Benefits: Precise ...
Pepperl+Fuchs offers a wide variety of industrial sensors for sheet fed printing applications ... immunity to interference from reflective surfaces SafeBox modular safety controller connects all safety components into one unit Pallet Detection Sensor Solution: Distance measurement UB500-18GM, UB500-F54, UC500-L2, VDM28 Customer Benefits: Reliable ...
Automatic doors, elevators, escalators, barriers or public transport: the sensors from the Pepperl+Fuchs portfolio are suitable for a wide range of applications in entrance automation ... on Automatically Extending Footboards Non-contact position and distance measurement is required to safeguard the boarding systems of trams. For this purpose, UB500 series ultrasonic sensors are installed in automatically extending footboards, where they measure ...
1-5/5Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.