Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Voltage output 0 V ... 5 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 10 V, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 5 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 5 V, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 5 V, Signal [2]: 1 x 1 ... 5 V, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 20 mApa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 5 V, Current output 4 mA ... 20 mA, Accuracy 0.1 %, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 5 V, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 4 ... 20 mApa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 10 V, Signal [2]: 1 x 2 ... 10 V, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 20 mApa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Current output 4 mA ... 20 mA, Accuracy 0.1 %, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 10 V, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 4 ... 20 mApa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Voltage output 1 V ... 5 V, Accuracy 0.1 %, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 1 ... 5 Vpa
Fire protection on ships is a very current and important issue Intelligent safety relays guaranteereliable switching processes and additional diagnostic functions Learn more about the latest additio ... or opens the circuit accordingly. Defective contacts are detected, and a fault is reported to the control system. After switching three times, the relay module is fully tested without any additional effort. The modules in the KFD2-RSH series also provide ...
Faulty fuel lines are common causes of fires in engine rooms KFD2-RSH-1*D* safety relays with dual redundant contacts from Pepperl+Fuchs enable the immediate shutdown of the fuel supply and offer maximum functional safety Learn more ... fuel, it is therefore important to immediately shut down the fuel pumps before any other measures are taken. This process must be fully automatic and take place properly even under critical operating conditions. The Solution KFD2-RSH-1.*D.* safety ...
Pepperl+Fuchs' VisuNet FLX line offers you the freedom and flexibility to customize an HMI solution that exactly fits your needs-whether you are looking for a full HMI system, panel PC, thin client or ... (32 … 104 °F) VisuNet FLX Extended Temperature Range RM-320S-*B-* (Remote Monitor) PC-320S-*B-* (Industrial PC) DM-320S-*B-* (Direct Monitor) 21,5” (16:9, Full HD: 1920x1080 px), 300 cd/m², optically bonded Non-Ex ATEX/IECEx Zone 2/22 UL Class I, II ...
The ETS safety relays (energized-to-safe) from Pepperl+Fuchs enable safe triggering of fire alarms and automatic extinguishing system in the event of a fire outbreak Learn more about the application ... in the event of a fire outbreak is safe signal transmission supplemented by galvanic isolation between the control and field circuits. The ETS safety relays (energized-to-safe) from Pepperl+Fuchs are designed precisely for this purpose. The KFD2-RSH-1.2E.L ...
See Overview: Pepperl+Fuchs offers a wide range of frequency converters for our K-System isolated barriers ... on the front of the unit the setting can also take place using a PC. Versions with wide range power packs are also available for international application. Five device versions are available: Downtime monitor KFD2-SR2-**2.W.SM The KFD2-SR2-Ex2.W.SM downtime ...
1-5/9Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.