Not available for purchase: 1-channel isolated barrier, 24 V DC supply (bus powered), Output 40 mA at 11.2 V DC, 52 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Housing width: 18 mm, Number of channels: 1-channel, Rated voltage: 20.4 ... 30 V via Termination Boardpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (bus powered), Output 40 mA at 11.2 V DC, 52 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Housing width: 18 mm, Number of channels: 2-channel, Rated voltage: 20.4 ... 30 V via Termination Boardpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 60 mA at 13 V DC, 65 mA current limit, Gas group IIB, Contact or logic control input, Line fault detection (LFD) with separate output, Up to SIL 2 acc. to IEC 61508 (bus powered), Up to SIL 3 acc. to IEC 61508 (loop powered), Housing width: 18 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3pa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact, mag pickup, NAMUR or current/voltage inputs, Configurable by PACTware or DIP switches, Current or voltage output, Sink and source mode output, Relay contact output, Line fault detection (LFD), Housing width: 18 mm, Number of channels: 1-channel, Rated voltage: 20.4 ... 30 V DCpa
Not available for purchase: Output type: Analog voltage output, Installation: flush, Operating voltage: 8 V, Connection type: PVC lead, Housing material: PBT, Degree of protection: IP65fa
Not available for purchase: Output type: Analog current output, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: cable PVC , 2 m, Housing material: brass, nickel-plated, Degree of protection: IP67fa
Not available for purchase: Output type: Analog current output, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: cable PVC , 5 m, Housing material: brass, nickel-plated, Degree of protection: IP67fa
Not available for purchase: Output type: Analog current output, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Type of voltage: DC, Operating voltage: 15 ... 30 V DC, Connection type: terminal compartment, Housing material: PBT, Degree of protection: IP67fa
Not available for purchase: Output type: Analog current output, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Type of voltage: DC, Operating voltage: 15 ... 30 V DC, Connection type: screw terminals, Housing material: PBT, Degree of protection: IP67fa
Not available for purchase: Output type: Analog current output, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Connection type: cable PVC , 2 m, Housing material: brass, nickel-plated, Degree of protection: IP67fa
The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas Learn more about the USi-safety ultrasonic sensor system ... in Accordance with Category 3 PL d Ultrasonic Technology for Safety in All Areas The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can ...
In autonomous transport, the direction of travel and the side areas of AGVs must be monitored in order to avoid any collision with people and objects The USi-safety ultrasonic sensor systems reliably detect all obstacles in a defined safety area ... standard, category 3 PL d . The Solution USi-safety ultrasonic sensor system Several USi-safety ultrasonic sensors are distributed on each side of the vehicle. The very compact sensor unit can be mounted in places where other types of sensor would not fit ...
Whether on-road or off-road, sensors used in mobile equipment must work reliably in harsh conditions Pepperl+Fuchs offers a broad portfolio of sensor solutions for mobile machines ... With the USi-safety , ultrasonic sensor technology can be used in accordance with Category 3 PL d for the first time. Be it reliably preventing collisions, or monitoring an area, the USi-safety system is ideally suited for challenging outdoor applications ...
See Overview: Pepperl+Fuchs diffuse mode and retroreflective mode ultrasonic sensors place the transmitter and receiver in the same housing ... with Category 3 PL d USi-safety Ultrasonic Sensor System The USi-safety ultrasonic sensor system is breaking new ground for safety applications —whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can be reliably protected ...
See Overview: Our ultrasonic sensors present the ideal solution for non-contact position and distance measurement in all industrial areas Contact us for enquiries! ... of the sensors. NEW! Reliable Safeguarding in Accordance with Category 3 PL d USi-safety Ultrasonic Sensor System The USi-safety ultrasonic sensor system is breaking new ground for safety applications —whether in challenging, dusty environments or in outdoor ...
1-5/13Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.