Up to 5000 ppr, Flameproof enclosure, Worldwide certification: ATEX, IECEx, KOSHA, CCC, Degree of protection IP66 / IP67, High shaft load capacity, Enclosure type: 70 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental or RS-422, incremental, Application: Ex protection, Detection type: photoelectric sampling, Output type: push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information)fa
Up to 5000 ppr, Flameproof enclosure, Worldwide certification: ATEX, IECEx, EX-approval for mining, Degree of protection IP66 / IP67, Enclosure type: 70 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental or RS-422, incremental, Application: Ex protection, Detection type: photoelectric sampling, Output type: push-pull, incremental or RS 422, incremental (see "Output circuit" in the ordering information)fa
Sturdy design, Up to 5000 ppr, 10 V ... 30 V with short-circuit proof push-pull output, Enclosure type: 78 mm, Type of shaft: Solid shaft, Interface: push-pull, incremental, Output type: push-pull, incrementalfa
Industrial standard housing ∅58 mm, 1024 or 2048 signal periods, Servo or clamping flange, Temperature compensated, interpolateable voltage signals, Output type: sine / cosinefa
Safe rotary encoder, thanks to integrated functional safety, Usable up to SIL 3 acc. to IEC 61508 , TÜV certified, Suitable as motor feedback system for safe drives in accordance with IEC 61800-5-2, Incremental encoder with sin/cos interface, Enclosure type: 58 mm, Type of shaft: Solid shaft, Interface: sine / cosine, Application: Safety Function, Detection type: photoelectric sampling, Output type: sine / cosinefa
1024 or 2048 signal periods, Flameproof enclosure, Worldwide certification: ATEX, IECEx, KOSHA, CCC, Degree of protection IP66 / IP67, High shaft load capacity, Enclosure type: 70 mm, Type of shaft: Solid shaft, Interface: sine / cosine, Application: Ex protection, Detection type: photoelectric sampling, Output type: sine / cosine fa
Various enclosure materials available, Ex d, Ex e and Ex tD certified, Safe protection for various instruments, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66 / IP67pa
Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Ex db eb and Ex tb certified, Various contact configurations and pole numbers, Glass reinforced polyester (GRP) or stainless steel enclosures, Padlockable switch, Labeling '0 - I', Function-adequate cable gland configurations, Degree of protection: IP 66, Function: switch disconnector, Enclosure: carbon loaded, antistatic glass-fiber reinforced polyester (GRP) or AISI 316L, (1.4404) stainless steelpa
Not available for purchase: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Not available for purchase: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Not available for purchase: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
Not available for purchase: Protection module for 1 supply line, Type 2 acc. to EN 61643-11, Exchange device for surge protection barrier M-LB-*.275*.D, Easy replacement of protection modules wihtout tools, High discharge capacity, Module can be exchanged under voltage (hot swap), Device type: type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1, Number of protected supply lines: 1pa
Not available for purchase: Switching function: Normally open/closed (NO/NC) programmable, Output type: AS-Interface, Installation: non-flush, Output type: 2-wire, Construction type: VariKont L®, Series: VariKont L®, Operating voltage: 26.5 ... 31.9 V via AS-i bus system, Type of voltage: DC, Connection type: Connector plug M12 x 1 , 4-pin, Housing material: PA, Degree of protection: IP67fa
Interfacetechnology from Pepperl+Fuchs,a leadingmanufacturer of interfaces for hazardousareas, offers a widerange of components and solutions for applications in processíndustries ... : longercable or fasteroperation of boostersolenoids, in case of safety-relatedapplications: SIL3ESDsystems and DCSsystems that needLFT to get the SILlevel for the DOcards/channelsSewageTreatmentPlants: SpeedMonitoring of ArchimedeanScrews ...
From the batterycell to the batterymodule to the batterypack: Pepperl+Fuchsofferspowerfulsensortechnology for automatedbatteryproduction ... efficiency. Pepperl+Fuchsalsooffers a widerange of compatiblesensorsolutions for othertasksrelated to solar and windpowerplants. Learn more ElectronicsIndustryBatterymanufacturing is one of the majorgrowthareas in the globalelectronicsindustry ...
The WCS is designed for applications with extremeambient conditions or especiallylongdistances ... PositionEncodingSystem | WCSWCSBenefitsModularDesignWCSVarietiesCodeRails and ID-PadsMountingSystemsApplicationsContact The absolutebenchmark. Provensystem with maximumprecision – even in extremeweather, dirt, and harsh ...
Learn more about the safeabsolutelinearpositioningsystems from Pepperl+Fuchs for safetyapplicationsup to SIL3 and PLe ... , and mechanicalstress. The safeWCS/PUSpositioningsystemmakessafeabsolutepositioningup to SIL3/PLeeven in such harshenvironmental conditions possible. With itsrobustoutdoorprotectivehousing with IP69degree of protection, it is sealedagainst ...
Get an overview of Pepperl+Fuchs' broadportfolio of HMIsystems for processindustries ... includesHMIsystems, panel and boxPCs. The modularityallowsthinclient and displayunits or powersupplies to be easilyreplaceddirectly in the field. VisuNetFLXEdge The VisuNetFLXEdgeseriesprovidesusers with an all-weatheroperatorstation ...