Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 4 mA ... 20 mA, Current output 0 mA ... 20 mA, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 4 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 20 mApa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 4 mA ... 20 mA, Voltage output 0 V ... 5 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 4 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 5 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 0 mA ... 20 mA, Voltage output 0 V ... 10 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 20 mA, Signal [2]: 1 x 4 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 10 V, Signal [2]: 1 x 2 ... 10 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Current input 4 mA ... 20 mA, Voltage output 0 V ... 10 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 4 ... 20 mA, Field device: 1 x I/P converters, Field device [2]: 1 x positioner, Signal: 1 x 0 ... 10 Vpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 10 V, Voltage output 0 V ... 10 V, Accuracy 0.1 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Transfer direction: to the field, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Signal: 1 x 0 ... 10 V, Signal [2]: 1 x 0 ... 5 V, Signal [3]: 1 x 1 ... 5 V, Signal [4]: 1 x 2 ... 10 V, Field device: 1 x I/P converters, Field device [2]: 1 x positionerpa
Fieldbus: Commissioning with Advanced Diagnostic Tools The Advanced Diagnostic Module from Pepperl+Fuchs monitors the fieldbus physical layer during operation Measurements are accessible in the cont ... or falling edges with 1 V peak-to-peak. This makes fieldbus communication very stable and resistive to disturbances. During commissioning, all relevant measurements receive warning levels with dead bands. Any relevant change to the fieldbus cable causes ...
Pepperl+Fuchs’ LoRaWAN based ultrasonic sensor WILSEN is a sturdy solution for fill level monitoring and distance measurement ... and Operation The WILSEN.sonic sensors can be conveniently configured for their intended purpose via downlink channel remote access or directly on site with a mobile device app (Android or iOS). Maximum Precision and Flexibility Thanks to a resolution of up to 1 ...