Not available for purchase: 1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms ... 60 min, Reset function, Lead breakage (LB) and short-circuit (SC) monitoring, Housing width: 40 mm, Number of channels: 1-channelpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Reset function, Time function, Rated voltage: 115 V AC ± 10 %, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detectionpa
Not available for purchase: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Rated voltage: 115 V AC ± 10 %pa
Not available for purchase: 1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms ... 60 min, Reset function, Lead breakage (LB) and short-circuit (SC) monitoring, Housing width: 40 mm, Number of channels: 1-channelpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Reset function, Time function, Rated voltage: 230 V AC ± 10 %, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detectionpa
Not available for purchase: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Rated voltage: 230 V AC ± 10 %pa
Not available for purchase: 1-channel, Control circuit EEx ia IIC, Switching amplifier with timing, Maximum input frequency 80 Hz, 1 relay output, 1 potential-free electronic output, Pulse divider up to 1 kHz, Time function: one shot output, one shot output retrigger, pulse extension, pulse limitation , on-delay, off-delay, auxiliary switch, Time range of the output function from 10 ms ... 60 min, Reset function, Lead breakage (LB) and short-circuit (SC) monitoring, Housing width: 40 mm, Number of channels: 1-channelpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Rated voltage: 20 ... 30 V DCpa
Not available for purchase: 1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD), Housing width: 40 mm, Number of channels: 1-channel, Reset function, Time function, Rated voltage: 20 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detectionpa