Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Photoelectric sensors with Pulse Ranging Technology (PRT) are ideal for a variety of applications ... Multiple, wide-beam emitters ensure reliable object detection regardless of surface structure Measurement using eye-safe LED technology 88° scanning angle Measuring range of 0.2 m to 8 m → To the R2100 multiray LED scanner R1000 Distance Sensor The R1000 ...
Automatic doors, elevators, escalators, barriers or public transport: the sensors from the Pepperl+Fuchs portfolio are suitable for a wide range of applications in entrance automation ... -efficient operation of the escalators. Safe Activation The ML100 retroreflective sensors with miniature housing are used to monitor whether people are climbing an escalator or even moving in the opposite direction of travel. In both cases, the sensor sends ...
Pepperl+Fuchs offers you an end-to-end IO-Link system solution that includes a range of IO-Link sensors and infrastructure ... -Based Applications (ICE1*) The ICE1* series IO-Link masters enable the connection of up to eight IO-Link devices. They ensure consistent diagnostics and parameterization from the control level to the sensor level and significantly increase system ...
With Ethernet IO modules from Pepperl+Fuchs reduce communication expenditure, expand efficiency and support a uniform system design Learn more about the fieldbus modules ... . Supports 8 IO-Link channels for sensors (Type A) and actuators (Type B) Is based on simple and economical wiring with unshielded standard cables Is future-proof thanks to IO-Link standard IEC 61131-9 Decentralized Logic Simplifies PLC Software With local ...
Web fed printing applications are solved with ultrasonic sensors or photoelectric sensors from Pepperl+Fuchs ... Precise resolution Insensitive to dust, oil, and grease Web Break Monitoring Sensor Solution: Photoelectric sensors MLV41-8-HV and ultrasonic sensors UB120-12GM Customer Benefits: Easy setup and diagnostics Reduces scrap Tamperproof or adjustable ...
See Overview: Pepperl+Fuchs offers FB Remote I/O FB Remote I/O stations are mounted in hazardous areas Zone 1 or Zone 21 ... switching functions in Zone 1 explosion-hazardous areas, Pepperl+Fuchs provides relay output modules with Ex e terminals . They are available in 2-, 4- and 8-channel versions. Power Supply Remote I/O power supplies are available in 24 V DC, 115 V AC ...
An inductive sensor switches at a certain distance from the metallic object This distance is referred to as the "operating distance" Learn more about this key characteristic ... , within which actuation of the sensor is assured under set conditions: 0 < s a ≤ 0.81 · s n Repeat Accuracy R The repeat accuracy R is the change in the effective operating distance s r , measured under the following conditions: Period: 8 hours Housing ...
Purge and pressurization is the most flexible Ex protection method, because it allows the use of non-Ex electrical equipment in hazardous areas Get to know how our Bebco EPS® purge+pressurization sys ... (lbs/sq in) x 144 (sq in/sq ft) = 166 pounds. The purge time = 4 volume exchanges x 22.5 sq.ft. / 30 scfm = 3 min Using 12 scfm for purging flow, the enclosure pressure will be around 2 in wc or 0.0725 psi. The force on this door will be 8 (sq ft) x ...
61-70/81Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.