Not available for purchase: 1-channel, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL 2 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 1-channel, HART communication, Rated voltage: 20 ... 35 V DC, Input signal: 0/4 ... 20 mApa
The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas Learn more about the USi-safety ultrasonic sensor ... the system with single-fault tolerance in accordance with EN ISO 13849-1. In addition to the connections for the ultrasonic sensor units and the safe, short-circuit, and crossed-circuit monitored OSSD outputs, there is an input for a temperature sensor ...
See Overview: Pepperl+Fuchs offers 24 VDC, 115 V AC and 230 VAC power supplies for our FB Zone 1 remote I/O systems ... and com units/gateways mounted on the corresponding backplane. The FB remote I/O power supplies feature galvanic isolation to mains power and can be operated in redundancy mode . ...
See Overview: Pepperl+Fuchs offers analog output modules for our FB Zone 1 remote I/O systems, 1- and 4-channel to control 0/4-20 mA HART positioners, proportional valves and indicators ... in the following versions: 1-channel versions address the needs of users who value system granularity and easy commissioning. 4-channel versions ensure the highest possible utilization of backplanes for module connection and enable compact remote I/O solutions ...
See Overview: Pepperl+Fuchs offers digital output modules for our FB Zone 1 remote I/O systems, 1-channel with position feedback and 8-channel for valves, LEDs and audible alarms ... Pepperl+Fuchs provides digital output modules for control of intrinsically-safe solenoid valves, LED clusters, beacons, horns, or other standard switching functions. As part of the FB system remote I/O solution , these digital outputs feature ...
See Overview: Pepperl+Fuchs offers temperature input modules for our FB Zone 1 remote I/O systems 1- and 4-channel temperature input modules for Pt 100 resistance thermometers, slide wire sensors, thermocouples and mV signals ... Temperature measurement is one of the most safety-critical applications in process automation—especially in explosion-hazardous areas . For this challenging task, Pepperl+Fuchs’ FB system remote I/O solution includes temperature inputs ...
See Overview: Pepperl+Fuchs offers field units and redundant field units for our FB Zone 1 remote I/O systems ... stainless steel and features slots for 24 double-width or 48 single-width I/O modules in an 800 x 1000 x 300 mm enclosure. It is suitable for use in a -20 °C … +40 °C temperature range (depending on power supply) and a rated voltage of 24 V DC/115 V AC/230 V ...
See Overview: Pepperl+Fuchs offers voltage input modules for our FB Zone 1 remote I/O systems 1-channel for connecting analog input signals with a voltage range of 0-10V ... of protection Ex ia terminals and are suited for use in Zone 1 explosion-hazardous areas . As 1-channel versions , they are perfect for users who value system granularity and easy commissioning. Galvanic isolation separates the inputs from bus and power ...
See Overview: Pepperl+Fuchs offers relay output modules for our FB Zone 1 remote I/O systems 2-, 4- and 8- channel modules for valves, solenoid valves, optical and audible alarms ... the highest flexibility for individual configuration of their remote I/O system . Galvanic isolation separates the modules’ outputs from bus and power. In addition, the relay outputs are hot-swappable, which allows quick and easy module replacement ...
See Overview: Pepperl+Fuchs' modular Remote I/O systems, LB, and FB, connect field signals in the hazardous and the safe areas ... without stopping the PROFINET controller. FB (Zone 1) FB remote I/O is certified for mounting in Zone 1 , placing the remote I/O system close to field devices, and it is installed in an enclosure. This modular signal conditioning system allows you to interface ...
See Overview: lorem ... for applications such as operation of pressure transmitters, flow transmitters, differential pressure transmitters, level transmitters, and proportional valves, I/P converters, or local indicators. Each of the four channels can be independently parameterized ...
1-10/338Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.