Optical data coupler for fast Ethernet, 150 m detection range, infrared light, 100 Mbit/s data rate, M12 plug, Independent of Ethernet protocol, TCP/IP, PROFINET, PROFIsafe, EtherCAT, FSoE, EtherNet/IP™, Ethernet POWERLINK etc., Plug connection for fast mounting, No parameterization, Line indicator for signal strengthfa
Optical data coupler for fast Ethernet, 300 m detection range, infrared light, 100 Mbit/s transfer rate, M12 plug, Independent of Ethernet protocol, TCP/IP, PROFINET, PROFIsafe, EtherCAT, FSoE, EtherNet/IP™, Ethernet POWERLINK etc., Plug connection for fast mounting, No parameterization, Line indicator for signal strengthfa
Optical data coupler for fast Ethernet, 150 m detection range, infrared light, 100 Mbit/s data rate, M12 plug, Independent of Ethernet protocol, TCP/IP, PROFINET, PROFIsafe, EtherCAT, FSoE, EtherNet/IP™, Ethernet POWERLINK etc., Version for low temperature applications, Plug connection for fast mounting, No parameterizationfa
Optical data coupler for fast Ethernet, 300 m detection range, infrared light, 100 Mbit/s transfer rate, M12 plug, Independent of Ethernet protocol, TCP/IP, PROFINET, PROFIsafe, EtherCAT, FSoE, EtherNet/IP™, Ethernet POWERLINK etc., Version for low temperature applications, Plug connection for fast mounting, No parameterizationfa
Pepperl+Fuchs worldwide manufacturing sites are certified to ISO 14001, ISO 80079-34 or ISO 9001 ... Manufacturing Inc., Katy/USA DEMKO 10 ATEX Q136467 US/UL/QAR07.0005 CML 21UKQAN13870-3 ISO 27001 Information Security Management System Pepperl+Fuchs SE, Germany DIN EN ISO/IEC 27001:2017 Contact Us Contact Us View All Subsidiaries+ Distributors Directions ...
New product family KFU8-SR* - switch amplifiers with wide range power supply ... range supply with 19...30 VDC or 90...253 VAC Single and 2-channel solutions Reversible operating direction Line fault monitoring International certifications: ATEX, IECEx, UL SIL 2 ed2 according to IEC/EN 61508 ...
Explore the Pepperl+Fuchs knowledge base to learn more about the different versions of inductive sensors ... distance (sr) under set conditions. The value defines the switch point accuracy of successive switch events over a period of eight hours at an ambient temperature of +23 °C ±5 °C and at a constant operating voltage. Switching Hysteresis According to EN ...
An inductive sensor switches at a certain distance from the metallic object This distance is referred to as the "operating distance" Learn more about this key characteristic ... specified in the EN 60947-5-2 standard or consists of a different material, this reduces the operating distance. The arrangement of the sensor and damping element must be customized such that the reduced operating distance is taken into account. Actuation ...
Pepperl+Fuchs is expanding its portfolio of universal isolated barriers with the HiC2422 intrinsic safety barrier ... density of 6 mm/channel and saves valuable space in the control cabinet. Due to its global certifications (ATEX, IECEx, UL), the HiC2422 can be used worldwide at ambient temperatures of -40 °C ... +70 °C . Certified up to SIL 2 (SC 3) according to IEC/EN ...
Precise alignment of heliostats in solar tower power plants using rotary encoders and tilt sensors Sensors that detect positions along two axes ... , and mechanical effects) Pulse count: max. 7,200 Operating temperature: –40°C … +100°C Degree of protection: DIN EN 60529, IP67, IP68, IP69K The Benefits Both sensor series include device versions that have been specially adapted for use in this application ...
Visit Pepperl+Fuchs’ press room for press releases, media kits and other information about industrial sensors and explosion Protection ... . (April 2021) Download Now Press Kit HANNOVER MESSE 2021 Preview (Division Factory Automation) In this press kit: Articles on the USi® safety, the world's only ultrasonic sensor with safety certification in accordance with EN ISO 13849 category 3 PL d ...
A combination of a pressure transmitter with a transmitter power supplyl is ideally suited for constantly monitoring the oil pressure in lubrication cycles ... power supply unit provides an intrinsically safe power supply and ensures that the data is reliably transmitted. KCD2-STC-Ex1.ES modules are typically used for this application. They are suitable for applications up to SIL 3 in accordance with IEC/EN ...
Explore the Pepperl+Fuchs knowledge base to learn more about the ambient conditions of inductive sensors ... tools where they are flushed by cooling liquids. Degrees of Protection Depending on the requirements, inductive sensors are protected according to IP65, IP67 , or IP68 (EN 60529) . Versions with degree of protection IP69K are available ...
Pepperl+Fuchs' rotary encoders are used to slow and control the speed of a process, resulting in increased efficiency ... +Fuchs includes sensors that have been designed for safety-relevant considerations. These sensors are TÜV-approved for certification in the highest safety categories such as SIL3 as per IEC 61508 or PL e as per EN ISO 13849-1. Interaction with the actual ...
41-50/61Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.