Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, PNP output, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching statefa
Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, NPN output, fixed cable, Miniature design, Detects transparent materials, Full metal thread mounting, Not sensitive to ambient light, The extra-large light spot makes the device insensitive to vibrations and skewing of the objectfa
Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, NPN output, fixed cable with M12 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching statefa
Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, PNP output, fixed cable, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching statefa
Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, PNP output, fixed cable with M12plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching statefa
Diffuse mode sensor with rectangular light spot for clear object detection, 200 mm detection range, red light, light/dark on, sensitivity adjuster, DC version, NPN output, M8 plug, Miniature design, Easy to use, Very bright, highly visible light spot, Full metal thread mounting, Highly visible LEDs for Power ON and switching statefa
See Overview: The actuator sensor interface (AS-Interface) with special yellow flat cable supplies power to sensors and actuators and allows you to transfer data to a maximum of 62 nodes per AS-Interf ... decoupling to provide power and send modulated signals along a cable without interference. Control cabinet power supplies are available with 2.8 A, 4 A, or 8 A for high efficiency. The AS-Interface K19 is a NEC Class 2 power supply. The ground fault monitor ...
See Overview: Pepperl+Fuchs offers a variety of sensor cables, connectors, and splitters for industrial automation ... . PVC, PUR, PUR Automotive, POC for welding areas), lengths, additional connection types ( M23, 1/2", 7/8” ), UL approval , and optional LEDs and sheathing colors enable individualized sensor cables. These tailor-made solutions are ideally suited ...
See Overview: Pepperl+Fuchs offers float switches for liquid level measurement ... Measuring principle Float switches are used for simple limit value detection in liquids. Due to the higher density of the liquid, the float switch floats on the liquid surface. The float switch is secured by means of its cable fastener at a level ...
See Overview: Enviro-Line purging units and pressurization systems from Pepperl+Fuchs are an enclosure pressurization system for non hazardous areas ... in order to prevent the accumulation of damaging and caustic gases and dusts. The elimination of these gases and dusts extends the life of expensive electrical equipment and instrumentation placed within the Enviro-Line purging unit. Due to higher pressures ...
The different objects on load carriers need to be identified correctly Pepperl+Fuchs offers RFID systems that are ideally suited for installation in vehicles ... thermal and mechanical stress, and must not be affected by EMC interference. The same applies to signal transmission interference due to metal or liquids in the surrounding environment. The Solution F190 Read/Write Head The F190 series read/write head ...
See Overview: Backplane FB Remote-I/O-System for Zone 1 ... and dual-width remote I/O modules, giving users high flexibility when configuring individual remote I/O solutions. The power supply and fieldbus connection is established on the left side. Due to a modular design concept , a base backplane can ...
Pepperl+Fuchs Segment Checker is a software tool that allows you to build, validate, edit, and save multiple fieldbus projects ... on Windows 8, Windows 8.1 and Windows 10. Extract the .ZIP-Archiv to a temporary folder. Launch the setup program (filename SETUP.EXE). The Setup Wizard appears. Follow the instructions of the wizard. Find more information in the User's Manual . FAQs What ...
Asynchronous motors or generators require high-precision speed control For such applications, Pepperl+Fuchs has expanded its portfolio of hollow shaftrotary encoders with the ENI90 series Discover ... wind farms. The robust ENI90HD heavy-duty rotary encoder series is used in steel mills to ensure reliable operation. High Mounting Flexibility and Extensive Accessories Due to standard tapped holes in 60° increments , all three variants of the ENI90 ...
Pepperl+Fuchs' R10x series photoelectric distance sensors are used for quality control in production plants ... sensors working in these environments have to be space saving and suitable for wider temperature ranges . Solution Due to their extremely precise light spot, the R10x series detect the smallest notches. The compact distance sensors in the R10x series ...
See Overview: BLE beacons are small radio beacons for Zone 1/21 and Div 1 that emit a signal in periodic intervals Learn more about the solution for localization, lone worker protection, physical ac ... by means of geolocation at a distance of up to 200 m . Due to the UV-resistant housing material, which withstands temperatures of -20°C ... +55°C, the Bluetooth® beacons are suitable for indoor and outdoor applications , and for use across different floors ...
101-110/300Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.