For extreme mechanical loads, Up to 5000 ppr, Stainless steel version, 10 V ... 30 V with short-circuit proof push-pull output, Output type: push-pull, incrementalfa
The new 5500 series is the latest addition to Pepperl+Fuchs Bebco EPS line of proven purge+pressurization systems ... Enclosure volumes to 250 ft 3 (7.08 m 3 ) Type Y Type Z 5500 Series Enclosure volumes to 250 ft 3 (7.08 m 3 ) Type Z Ex pzc 6000 Series Enclosure volumes to 250 ft 3 (7.08 m 3 ) Type X Ex pxb 6500 Series Enclosure volumes to 450 ft 3 (12.75 m 3 ) Ex pxb Ex ...
See Overview: Pepperl+Fuchs' Bebco EPS 6000 series Ex px/ Type X purging system is a complete automatic system that will purge and pressurize the protected enclosure and maintain pressure within the e ... / Class I and II, Division 1 to non-hazardous area applications Enclosure sizes up to 7.01 cubic meters. (250 cubic ft.) The Ex px / Type X system conforms to ATEX, NFPA 496 and ISA 12.4 DEMKO, UL cULus, IEC Ex Configure your 6000 Series System 6000 Series ...
See Overview: Multiturn absolute rotary encoders from Pepperl+Fuchs make it possible to record not only angular positions, but also the number of revolutions ... Multiturn absolute rotary encoders feature an integrated gear in addition to the code disk, resulting in over one billion measuring steps and a total resolution of up to 30 bits . This makes it possible to record not only the angular positions ...
See Overview: Our Pepperl+Fuchs Bebco EPS 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applicatio ... : Class II Enclosure Volumes ≤ 50 ft3 1001C : Class II Enclosure Volumes ≤ 250 ft3 1002 : Class I Enclosure Volumes ≤ 15 ft3 1003 : Class I Enclosure Volumes ≤ 75 ft3 1004 : Class I Enclosure Volumes ≤ 200 ft3 1005 : Class I Enclosure Volumes ≤ 450 ft3 11 ...
See Overview: Our Pepperl+Fuchs Bebco EPS 2000 series, Type Y purging system is an automatic system that will purge and pressurize the protected enclosure and maintain pressure within the enclosure ... Enclosure Volumes ≤ 50 ft3 1001C : Class II Enclosure Volumes ≤ 250 ft3 1002 : Class I Enclosure Volumes ≤ 15 ft3 1003 : Class I Enclosure Volumes ≤ 75 ft3 1004 : Class I Enclosure Volumes ≤ 200 ft3 1005 : Class I Enclosure Volumes ≤ 450 ft3 11 : Class I ...
Explore the Pepperl+Fuchs knowledge base to learn more about the ambient conditions of inductive sensors ... at the following maximum values: Sensors with "T" marking in the type designation: ≤ +100 °C Sensors with "150", "200", or "250" marking in the type designation: maximum operating temperature in each case in °C. For extremely low temperatures, there is no code ...
See Overview: Pepperl+Fuchs supply line protection devices protect main power supplies with 115/230 V against power surges ... These AC surge protection barriers protect mains power supplies with 30/115/230 V against destructive power surges. The pluggable modules feature front-sided indicators delivering operating state and error message outputs ensuring a quick and easy ...
The new ICE11 IO-Link master for PLC-based applications is multiprotocol-capable and now supports not only PROFINET, EtherNet/IP, and MODBUS TCP but also EtherCAT and CC-Link IE Field Basic It can be ... and can be used for real-time applications with cycle times down to the microsecond range, depending on the protocol used. For instance, the EtherCAT variant offers a ~250 µs cycle time. The devices also comply with the latest IO-Link standard V1.1.3 ...
Electronic circuit boards require unique product identification and tracking during the production process Data Matrix codes allow the highest data density in the smallest spaces, offering an ideal s ... and reliability In the 1990’s, creativity knew no bounds, and over thirty different symbologies were in existence. At the same time, the realization dawned that neither the user nor the producer of the essential technical equipment, (printers, reading equipment ...
Stacker cranes in high-bay warehouses are designed to achieve maximum throughput with reliable precision The industrial event camera VOC monitors the storage and retrieval processes and provides targ ... SD card stores up to 10,000 sequences Quick and easy classification of the relevant recording REST API for comprehensive integration into IT systems Temperature range –30° C to +50° C IP65 degree of protection The Advantages Unlike a continuous video ...
11-20/91Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.