See Overview: Pepperl+Fuchs' Compact Power Hub feeds eight (8) FOUNDATION Fieldbus H1 segments with redundancy of power supplies ... of ignition protection at the field device, utilizing the high-power trunk concept. They are flameproof enclosure Ex d and intrinsic safety Ex ia, Ex ib, or Ex ic acc. to FISCO/Entity for any hazardous location . Spring connectors with retaining screws: Easy ...
See Overview: Pepperl+Fuchs’ PROFIBUS PA power supplies include the Power Hub This modular, motherboard-based power supply system is used for one to four PROFIBUS PA segments ... common methods of ignition protection at the field device utilizing the high-power trunk concept. They are flameproof enclosure Ex d and intrinsic safety Ex ia, Ex ib or Ex ic acc. to FISCO/Entity for any hazardous location . Spring connectors ...
See Overview: BLE beacons are small radio beacons for Zone 1/21 and Div 1 that emit a signal in periodic intervals Learn more about the solution for localization, lone worker protection, physical ac ... by means of geolocation at a distance of up to 200 m . Due to the UV-resistant housing material, which withstands temperatures of -20°C ... +55°C, the Bluetooth® beacons are suitable for indoor and outdoor applications , and for use across different floors ...
Bebco EPS portfolio provides reliable safety for Zones and Divisions applications, with a full range of Type X,Y, Z, Ex px, and Ex pz Each system has been designed and engineered with a user-friendly ... Bluetooth Universal power 20 to 30 VDC / 100 to 250 VAC. 50 to 60 HZ Up to SIL 2 acc. to IEC 61508 6000 Series Fully automatic Type X & Ex pxb purge and pressurization system for hazardous gas or dust applications 100% automatic purge and pressurization ...
AMRs faultlessly detect pallet bases with the help of multipixel technology, which reliably suppresses background reflections during travel ... Technology (MPT) Optimal light spot size Sensing range of 40 mm to 400 mm Preconfigured to 200 mm Control LED for correct pallet base detection The Benefits The multipixel array and the optimal light spot geometry mean both smooth and textured surfaces can ...
Automatic doors in busses and trains require door edge protection to prevent the unintentional trapping of passengers Photoelectric sensors from Pepperl+Fuchs are used to solve this application ... to 5 light sensors with background elimination are incorporated in a light strip covering the whole door width. They cover the door area from above up to approx. 200 mm above the floor. Their function is therefore safeguarded even where ground ...
Ethernet-APL enables fast and efficient communication of large data volumes at a rate of 10 Mbit/s The two-wire cable transmits up to 92 W of data and power of simultaneously It also sets new standa ... is ensured by certification of protocol and physical layer. This means that devices work together easily, even where technology from different manufacturers is in operation. At a Glance Cable lengths of up to 1,000 m: spur up to 200 m, trunk up to 1,000 m ...
Contact Pepperl+Fuchs for technical support, complete product information and our international locations Pepperl+Fuchs is a global manufacturer of electronic sensors & a worldwide market leader for ... Contact Us Pepperl+Fuchs Global Headquarters World Headquarters Pepperl+Fuchs SE Lilienthalstraße 200 68307 Mannheim Germany +49 621 776 - 0 +49 621 776 - 1000 https://www.pepperl-fuchs.com North American Headquarters Pepperl+Fuchs Inc. 1600 ...
See Overview: Our Pepperl+Fuchs Bebco EPS 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applicatio ... : Class II Enclosure Volumes ≤ 50 ft3 1001C : Class II Enclosure Volumes ≤ 250 ft3 1002 : Class I Enclosure Volumes ≤ 15 ft3 1003 : Class I Enclosure Volumes ≤ 75 ft3 1004 : Class I Enclosure Volumes ≤ 200 ft3 1005 : Class I Enclosure Volumes ≤ 450 ft3 11 ...
See Overview: Our Pepperl+Fuchs Bebco EPS 2000 series, Type Y purging system is an automatic system that will purge and pressurize the protected enclosure and maintain pressure within the enclosure ... Enclosure Volumes ≤ 50 ft3 1001C : Class II Enclosure Volumes ≤ 250 ft3 1002 : Class I Enclosure Volumes ≤ 15 ft3 1003 : Class I Enclosure Volumes ≤ 75 ft3 1004 : Class I Enclosure Volumes ≤ 200 ft3 1005 : Class I Enclosure Volumes ≤ 450 ft3 11 : Class I ...