Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Long design (300 mm mounting depth), Connection via marshalling patchboards, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Long design (300 mm mounting depth), Connection via marshalling patchboards, With middle sheet and cable duct, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Short design (211 mm mounting depth), Connection via terminal blocks, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Subrack for K-System, Replacement for subrack of the E-System, Max. 33 slots for isolators, Short design (211 mm mounting depth), Connection via marshalling patchboards, Partial and combined assembly possible, Complete wiring according to customer requirements, Allows to retain cable routing in the switch cabinet, No structural changes on the switch cabinet requiredpa
Two new CB10 AS-Interface modules enable the integration of 3-wire sensors and emergency stop buttons according to SIL 3/PL e Learn more about their features and the fields of application ... 3/PL e CB10 module in conveyor technology. AS-Interface has long proven itself as a user-friendly and cost-effective wiring technology for the industrial sector. To increase the variety of available components and expand the range of possible ...
Explore the Pepperl+Fuchs knowledge base to learn more about the power source of three-wire sensors ... stages are referred to as PNP output stages. Sensor Connection—Example Example of a 3-wire sensor in direct-current voltage operation Special Type: Sensors with Digital Current Output A special type of switching 3-wire sensor is the sensor with a digital ...
Pepperl+Fuchs offers you easy access to safety values for many products ... in the documentation that allow building a category 3 application by using the devices in redundancy. Electronic devices with programmable electronics are mostly also evaluated to IEC 6206 1 and claim to have a SILcl which also allows the use within safety applications ...
See Overview: The WCS position encoding system from Pepperl+Fuchs includes interface modules with integrated RS-485 or SSI outputs ... that require a safety level up to SIL 3/PL e . For this purpose, two safeWCS/PUS read heads are combined with the safe evaluation unit (Position Unit Safe, PUS) . The safe evaluation unit acts as a safe gateway to the fieldbus: It processes the redundant ...
Standards for functional safety require the verification or validation of all activities and results according to the four-eyes principle ... 3. Assessing Functional Safety The FSM system of Pepperl+Fuchs is certified by exida according to IEC 61508:2010. Standards for functional safety require the verification or validation of all activities and results according to the four-eyes ...
Learn how to check battery modules for completeness and alignment—with a stereo-vision-sensor, generating high-precision 3-D images ... of the battery cells and ensure that they are aligned correctly within the module. This should take place immediately and without contact . The Solution 3-D-Vision-Sensors A vision sensor from the SmartRunner Explorer 3-D series uses stereo vision technology ...
The R2300 multi-layer scanner for 3D object detection and collision avoidance ensures the reliable navigation of autonomous vehicles for intralogistics Learn more about the R2300 3-D LiDAR sensor ... (10%) Measuring rate: 50 kHz Scanning angle: 100° Scan rate: 25/12.5 Hz Angular resolution: 0.1° Distance measurement accuracy: 30 mm (1 sigma) Measuring rate: up to 4,000 pixels per scan The Benefits A compact housing design ensures that the 3-D ...
See Overview: In addition to read heads and code tape, the Data Matrix positioning system portfolio also includes the appropriate accessories ... See Overview: In addition to read heads and code tape, the Data Matrix positioning system portfolio also includes the appropriate accessories ... ...
See Overview: The self-adhesive Data Matrix code tape is available with individual starting positions and in custom lengths of up to 100 km ... See Overview: The self-adhesive Data Matrix code tape is available with individual starting positions and in custom lengths of up to 100 km ... ...
Pepperl+Fuchs' ML100 Series photoelectric sensors include diffuse mode models ... with three new diffuse mode sensors . Along with the proven standardized series , these new types offer users advanced solutions for increasingly complex applications . Diffuse mode sensor with very wide visible light spot – ML100-8-W Diffuse mode sensor ...
11-20/240Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.