Serviceline Industrial Sensors
Serviceline Explosion Protection

High temperature identification system OIT500-F113-B17-CB

OIT500-F113-B17-CB
  • High-temperature code carrier up to 500 °C (932 °F)
  • PROFINET interface with integrated switch
  • Connection to Ethernet TCP/IP
  • Optional reading of CB3 code plates
  • Sturdy and compact design
  • Integrated illumination
  • High operating range
  • Large sensing range
  • High depth of focus

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  OIT500-F113-B17-CB

Product Description
Optical high temperature identification system, 300  to  450 mm
General specifications
Light sourceIntegrated LED lightning
Light typeInfrared
SymbologiesCB1: perforated matrix 6 x 6 6 decimal digits
Read distanceCB1: 300 ... 520 mm
Reading field335 mm x 185 mm at max. read distance
Evaluation frequency5 Hz
Target velocitytriggered max. 1.5 m/s
Functional safety related parameters
MTTFd86 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED indicationstatus , Function , communication
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
Operating current200 mA without output drivers
Interface 1
Interface type100 BASE-TX
ProtocolPROFINET IO Real-Time (RT)
Conformance Class B
Netload Class III
Transfer rate100 Bit/s
Interface 2
Interface typeEthernet
ProtocolTCP/IP
Transfer rate100 MBit/s
Input
Input voltage24 V DC low: < 8 V, high: > 12 V
Number/Type2 trigger input and supply
max. 4 switching inputs
Output
Number/Typesupply max. 200 mA and 1 control output for External lighting
max. 4 switching outputs programmable
Switching voltageoperating voltage minus voltage drop typ. 1.1 V
Switching current100 mA each output
Conformity
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Emitted interferenceEN 61000-6-4:2007+A1:2011
Noise immunityEN 61000-6-2:2005
Photobiological safetyEN 62471:2008 exempt group
Approvals and certificates
CE conformityCE
Ambient conditions
Ambient temperature0 ... 60 °C (32 ... 140 °F)
Storage temperature-20 ... 75 °C (-4 ... 167 °F)
Mechanical specifications
Degree of protectionIP67
Connection8-pin, M12x1 connector, standard (supply+IO)
2 x 4-pin, M12x1 socket, D-coded (LAN)
3 x 5-pin, M12x1 socket, A-coded
( Trigger , External lighting )
Material
Housingdiecast aluminum powder coated
Massapprox. 4000 g
Dimensions
Height101 mm
Width261 mm
Depth171 mm

Classifications

SystemClasscode
ECLASS 13.027280103
ECLASS 12.027280103
ECLASS 11.027280103
ECLASS 10.0.127280103
ECLASS 9.027280103
ECLASS 8.027280103
ECLASS 5.127280103
ETIM 9.0EC002999
ETIM 8.0EC002999
ETIM 7.0EC002999
ETIM 6.0EC002999
ETIM 5.0EC002999
UNSPSC 12.143211701

Details: OIT500-F113-B17-CB

Function

The OIT500-* stationary read device is an optical identification system that works using industrial vision methods and is used in automated manufacturing processes. The ambient conditions in painting facilities in particular, for example the cyclical temperature changes, often make the use of read-only tags with electronic components difficult if not impossible. For the OIT high-temperature identification system, read-only tags of solid metal plates with a perforated matrix are used, which are designed for use at temperatures of up to 500 °C and suitable for high mechanical stress.

Simple installation and commissioning without complicated, time-consuming Teach-In processes enable rapid entry. The integrated PROFINET interface enables simple integration into the controller.A scratch-resistant, replaceable quartz glass panel and sturdy metal housing make the OIT500-* a robust, efficient identification system.

Informative Literature: OIT500-F113-B17-CB

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Reliable Optical Identication in High-Temperature EnvironmentsENGPDF218 KB

Product Documentation: OIT500-F113-B17-CB

Language Selection:
ManualsLanguageFile TypeFile Size
ManualENGPDF13803 KB

Design / Simulation: OIT500-F113-B17-CB

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP11335 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ132 KB

Approvals: OIT500-F113-B17-CB

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Worldwide PNO Certificate of ComplianceZ12658ALLPDF83 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4583AALLPDF208 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-6626ALLPDF29 KB

Associated Products: OIT500-F113-B17-CB

Accessories

Female connector M12 straight A-coded 8-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa

Male cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Code carrier for optical high-temperature identification system, stainless steelfa
Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa
Replacement glass for series OIT300, OIT500 and OIT1500fa
Operating software for camera-based sensorsfa
Ethernet bus cable M12 plug straight D-coded to RJ45 Ethernet-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa