Fire protection retroreflective sensor MLV12-54-2563/49/124

MLV12-54-2563/49/124
  • Small fire protection photoelectric sensor for safety devices on fire barriers
  • Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol)
  • High protection against contact
  • Not sensitive to ambient light, even with switched energy saving lamps

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  MLV12-54-2563/49/124

Product Description
Small fire protection photoelectric sensor
General specifications
Effective detection range0 ... 2.1 m (with H60 reflector)
Reflector distance0.2 ... 2.1 m
Reference targetH60 reflector
Light sourceLED 645 nm
Light typemodulated visible red light
Diameter of the light spotapprox. 70 mm
Opening angle1.5 °
Ambient light limit50000 Lux
Indicators/operating means
Operation indicatorLED green, flashes in case of short-circuit
Function indicator2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted
Control elementsrotary switch for light/dark
Electrical specifications
Operating voltage10 ... 30 V DC
Ripplemax. 10 %
No-load supply currentmax. 40 mA
Protection classII, rated voltage ≤ 300 V AC with pollution degree 1-2 according to IEC 60664-1
Output
Switching typelight/dark on switchable
Signal output1 NPN and 1 PNP output, direct switching, short-circuit protected, reverse polarity protected, open collector
Switching voltagemax. 30 V DC
Switching currentmax. 0.2 A
Voltage drop≤ 2.5 V DC
Switching frequency≤ 40 Hz
Response time10 ms
Conformity
Product standardEN 60947-5-2
Standard conformity
StandardsEN 60947-5-2
smoke insensitive up to 2 dB/m ( EN 54-12 )
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
CCC approvalCCC approval / marking not required for products rated ≤36 V
ApprovalsVdS/DIBt certificate of compliance No. 25020 , approval number Z-6.510-2295
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 75 °C (-40 ... 167 °F)
Relative humidity30% ... 85%   non-condensing ; Non-icing
Mechanical specifications
Degree of protectionIP67
Connection5-pin M12 x 1 connector with metal thread, 90° rotatable
Material
HousingFrame: nickel plated, die cast zinc,
Laterals: glass-fiber reinforced plastic PC
Optical facePlastic pane
Mass60 g

Classifications

SystemClasscode
ECLASS 11.027270902
ECLASS 10.0.127270902
ECLASS 9.027270902
ECLASS 8.027270902
ECLASS 5.127270902
ETIM 8.0EC002717
ETIM 7.0EC002717
ETIM 6.0EC002717
ETIM 5.0EC002717
UNSPSC 12.139121528

Documents: MLV12-54-2563/49/124

Instruction leafletsLanguageFile TypeFile Size
Instruction leaflet / Beipackzettel ALLPDF368 KB

CAD+CAE: MLV12-54-2563/49/124

CADFile TypeFile Size
3-D model / 3-D-ModellSTP200 KB
3-D model / 3-D-ModellSTP200 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: MLV12-54-2563/49/124

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of Conformity / EU-KonformitätserklärungDOC-0916BPDF185 KB
Certificates
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
EU VdS union of non-life insurerReg.-Nr. 25020PDF1847 KB

Associated Products: MLV12-54-2563/49/124

Accessories

Female cordset single-ended M12 straight A-coded, 5-pin, PUR cable greyfa

Female connector M12 straight A-coded 5-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, UL approved, drag chain suitable, torsion resistantfa
Reflector with mounting holesfa
Mounting bracket for series MLV12 sensorsfa
Mounting bracket for series MLV12 sensorsfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
dove tail mounting clampfa
dove tail mounting clampfa
dove tail mounting clampfa

Function: MLV12-54-2563/49/124

It is essential that fire is not allowed to spread in buildings should it break out. Fire protection regulations therefore prescribe fire barriers. These include fire doors, industrial fire doors and fire dampers, which are generally kept closed at all times. In areas where doors are left open, such as heavily traveled passageways and corridors, a self-closing mechanism must be automatically triggered in case of fire. However, the door must not close when persons or objects are in the closing area. Legislation consequently requires monitoring with appropriate safety devices. The technical challenge is to ignore the smoke and at the same time reliably detect objects in it. These certified photoelectric sensors fulfill this function.

R10x and R20x series photoelectric sensors

For the first time, a consistent solution range of photoelectric functional principles and innovative technologies is available in identical housings. Users benefit from a uniform operating concept across the entire portfolio. Discover the R100, R101, R103, R200 and R201 series ...

ML100 Photoelectric Sensor

Whether glass, solar wafers or printed circuit boards: The photoelectric sensors of the ML100 series are precisely tailored to meet the requirements of various complex detection tasks. Learn more about the portfolio and find the ideal sensor for your application ...