Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
NCB40-FP-A2-P1-3G-3D
General specifications |
Switching function | complementary |
Output type | PNP |
Rated operating distance | 40 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 32.4 mm |
Reduction factor rAl | 0.25 |
Reduction factor rCu | 0.23 |
Reduction factor r304 | 0.85 |
Output type | 4-wire |
Nominal ratings |
Operating voltage | 10 ... 60 V DC |
Switching frequency | 0 ... 80 Hz |
Hysteresis | typ. 3 % |
Reverse polarity protection | reverse polarity protected |
Voltage drop | ≤ 3 V |
Operating current | 0 ... 200 mA |
Off-state current | 0 ... 0.5 mA |
No-load supply current | ≤ 20 mA |
Time delay before availability | ≤ 300 ms |
Operating voltage indicator | LED, green |
Switching state indicator | LED, yellow |
Functional safety related parameters |
MTTFd | 630 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates |
IECEx approval | |
| Equipment protection level Gc (ec) | IECEx TUR 21.0019X |
| Equipment protection level Dc (tc) | IECEx TUR 21.0020X |
ATEX approval | |
| Equipment protection level Gc (ec) | TÜV 20 ATEX 8525 X |
| Equipment protection level Dc (tc) | TÜV 20 ATEX 8526 X |
UL approval | cULus Listed, General Purpose |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type | screw terminals |
Information for connection | A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 % |
Core cross section | up to 2.5 mm2 , stripped insulation length: 7 mm |
| Minimum core cross-section | min. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors) |
| Maximum core cross-section | max. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors) |
Connection (system side) | screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm |
Housing material | PBT |
Sensing face | PBT |
Housing base | PBT |
Degree of protection | IP68 |
Tightening torque, housing screws | 1 Nm |
Dimensions | |
| Height | 40 mm |
| Width | 80 mm |
| Length | 80 mm |
General information |
Use in the hazardous area | see instruction manuals |
Classifications
System | Classcode |
ECLASS 13.0 | 27274001 |
ECLASS 12.0 | 27274001 |
ECLASS 11.0 | 27270101 |
ECLASS 10.0.1 | 27270101 |
ECLASS 9.0 | 27270101 |
ECLASS 8.0 | 27270101 |
ECLASS 5.1 | 27270101 |
ETIM 9.0 | EC002714 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |
Details:
NCB40-FP-A2-P1-3G-3D
Product Documentation:
NCB40-FP-A2-P1-3G-3D
Design / Simulation:
NCB40-FP-A2-P1-3G-3D
Approvals:
NCB40-FP-A2-P1-3G-3D