Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
NCB2-12GM40-Z0-V1
General specifications |
Switching function | Normally open (NO) |
Output type | Two-wire |
Rated operating distance | 2 mm |
Installation | flush |
Output polarity | DC |
Assured operating distance | 0 ... 1.62 mm |
Actual operating distance | 1.8 ... 2.2 mm typ. |
Reduction factor rAl | 0.28 |
Reduction factor rCu | 0.23 |
Reduction factor r304 | 0.7 |
Nominal ratings |
Operating voltage | 5 ... 60 V |
Switching frequency | 0 ... 800 Hz |
Hysteresis | 1 ... 10 typ. 5 % |
Reverse polarity protection | reverse polarity tolerant |
Short-circuit protection | pulsing |
Voltage drop | ≤ 5 V |
Operating current | 2 ... 100 mA |
Lowest operating current | 2 mA |
Off-state current | 0 ... 0.5 mA typ. |
Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters |
MTTFd | 2090 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type | Connector M12 x 1 , 4-pin |
Housing material | Stainless steel 1.4305 / AISI 303 |
Sensing face | PBT |
Housing diameter | 12 mm |
Degree of protection | IP67 |
Documents:
NCB2-12GM40-Z0-V1
CAD+CAE:
NCB2-12GM40-Z0-V1
Approvals+Certificates:
NCB2-12GM40-Z0-V1
Associated Products:
NCB2-12GM40-Z0-V1
Accessories |
|
|
|
Mounting flange, 12 mmfa |
|
|
|
|
Quick mounting bracket with dead stopfa |
|
|
|
|
Female cordset, M12, 4-pin, PUR cablefa |
|
|
|
|
Female cordset, M12, 4-pin, PUR cablefa |
|