Inductive sensor NBB1,5-F79-E3

NBB1,5-F79-E3
  • Basic series
  • 1.5 mm flush
  • 3-wire DC

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB1,5-F79-E3

General specifications
Switching functionNormally closed (NC)
Output typePNP
Rated operating distance1.5 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.215 mm
Reduction factor rAl 0.3
Reduction factor rCu 0.2
Reduction factor r304 0.7
Nominal ratings
Operating voltage5 ... 30 V DC
Switching frequency0 ... 1200 Hz
Hysteresistyp. 5 %
Short-circuit protectionpulsing
Voltage drop≤ 1.5 V
Operating current0 ... 100 mA
Off-state current≤ 10 µA
No-load supply current≤ 15 mA
Functional safety related parameters
MTTFd3910 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
EAC conformityTR CU 020/2011
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeflexible leads PVC , 500 mm
Core cross-section0.08 mm2
Housing materialPA
Sensing facePA
Housing diameter
Degree of protectionIP67

Documents: NBB1,5-F79-E3

Technical informationLanguageFile TypeFile Size
Installation conditionsENGPDF117 KB
EinbaubedingungenGERPDF118 KB

Approvals+Certificates: NBB1,5-F79-E3

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-0912BPDF170 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB