Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NCB1,5-8GM40-N0-V1-Y97264

NCB1,5-8GM40-N0-V1-Y97264
  • Comfort series
  • 1.5 mm flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NCB1,5-8GM40-N0-V1-Y97264

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance1.5 mm
Installationflush
Assured operating distance0 ... 1.215 mm
Actual operating distance1.35 ... 1.65 mm typ.
Reduction factor rAl 0.22
Reduction factor rCu 0.19
Reduction factor r304 0.65
Output type2-wire
Nominal ratings
Nominal voltage8 V
Switching frequency0 ... 5000 Hz
Hysteresis1 ... 10 typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 3 mA
Measuring plate detected≤ 1 mA
Switching state indicatorMultihole-LED, yellow
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approval
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CSA approvalcCSAus Listed, General Purpose
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
General information
Use in the hazardous areasee instruction manuals

Documents: NCB1,5-8GM40-N0-V1-Y97264

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF175 KB
Návod k poużitíCZEPDF166 KB
Instruktions manualDANPDF165 KB
Instruction manualENGPDF167 KB
KasutusjuhendESTPDF160 KB
KäyttöohjeFINPDF159 KB
Manuel d'instructionsFRAPDF169 KB
BetriebsanleitungGERPDF166 KB
Οδηγίες χρήσηςGREPDF177 KB
HandleidingHOLPDF165 KB
Instruction manual / BetriebsanleitungHRVPDF164 KB
Használati útmutatóHUNPDF171 KB
Manuale di istruzioniITAPDF166 KB
Lietošanas pamācībaLAVPDF165 KB
Instrukciju vadovasLITPDF165 KB
Instrukcja obsługiPOLPDF169 KB
Manual de instruçõesPORPDF168 KB
Manual de utilizareRONPDF168 KB
Návod na poużitieSLKPDF167 KB
Navodila za uporaboSLVPDF164 KB
Manual de instruccionesSPAPDF230 KB
ManualSWEPDF164 KB
Technical information
Installation conditionsENGPDF1053 KB
EinbaubedingungenGERPDF1054 KB

Approvals+Certificates: NCB1,5-8GM40-N0-V1-Y97264

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1653PDF265 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Hazardous LocationE501628:1:2PDF444 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
EU PTB ATEX ia 2G, 1G, 1D s. certificatePTB 00 ATEX 2048 XPDF29071 KB
Worldwide PTB IECEx iaIECEx PTB 11.0037XLINK---
Control drawings
Control drawing UL / Control drawing UL   PDF286 KB

Associated Products: NCB1,5-8GM40-N0-V1-Y97264

Accessories

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508pa

Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellowfa

Female cordset, M12, 2-pin, NAMUR, PUR cablefa

Female cordset, M12, 2-pin, NAMUR, PUR cablefa
Quick mounting bracket with dead stopfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.