Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NCB10-30GM40-Z0-V1-3G-3D

NCB10-30GM40-Z0-V1-3G-3D
  • 10 mm flush
  • ATEX-approval for zone 2 and zone 22

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NCB10-30GM40-Z0-V1-3G-3D

General specifications
Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance10 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 8.1 mm
Actual operating distance9 ... 11 mm typ. 10 mm
Reduction factor rAl 0.32
Reduction factor rCu 0.28
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Operating voltage5 ... 60 V DC
Switching frequency0 ... 150 Hz
Hysteresis1 ... 15 typ. 5 %
Reverse polarity protectionreverse polarity tolerant
Short-circuit protectionpulsing
Voltage drop≤ 5 V
Voltage drop at IL
Voltage drop IL = 20 mA, switching element on3.4 ... 5 V typ. 4.3 V
Operating current2 ... 100 mA
Off-state current0 ... 0.5 mA typ.
Time delay before availability≤ 50 ms
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1830 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP67
Equipment protection level Dc (tc)
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
General information
Use in the hazardous areasee instruction manuals

Documents: NCB10-30GM40-Z0-V1-3G-3D

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF158 KB
Návod k poużitíCZEPDF151 KB
Instruktions manualDANPDF150 KB
Instruction manualENGPDF151 KB
KasutusjuhendESTPDF146 KB
KäyttöohjeFINPDF145 KB
Manuel d'instructionsFRAPDF154 KB
BetriebsanleitungGERPDF151 KB
Οδηγίες χρήσηςGREPDF160 KB
HandleidingHOLPDF149 KB
Instruction manual / BetriebsanleitungHRVPDF149 KB
Használati útmutatóHUNPDF152 KB
Manuale di istruzioniITAPDF149 KB
Lietošanas pamācībaLAVPDF149 KB
Instrukciju vadovasLITPDF151 KB
Instrukcja obsługiPOLPDF153 KB
Manual de instruçõesPORPDF152 KB
Manual de utilizareRONPDF151 KB
Návod na poużitieSLKPDF151 KB
Navodila za uporaboSLVPDF149 KB
Manual de instruccionesSPAPDF151 KB
ManualSWEPDF148 KB
Technical information
Installation conditionsENGPDF1053 KB
EinbaubedingungenGERPDF1054 KB

Approvals+Certificates: NCB10-30GM40-Z0-V1-3G-3D

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1367APDF52 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
China CQC CCC2020970305001202PDF605 KB
Europe Pepperl+Fuchs ATEX Category 3 D CertificatePF15CERT3774XPDF1001 KB
Europe Pepperl+Fuchs ATEX Category 3 G CertificatePF15CERT3754XPDF1015 KB

Associated Products: NCB10-30GM40-Z0-V1-3G-3D

Accessories

Mounting flange, 30 mmfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.