Datasheet excerpt: Technical data of  NBN8-12GM50-E2-V1

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance8 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) )
0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) )
Reduction factor rAl 0.39
Reduction factor rCu 0.3
Reduction factor r304 0.7
Reduction factor rBrass 0.45
Nominal ratings
Operating voltage10 ... 30 V
Switching frequency0 ... 1500 Hz
Hysteresistyp. 5%
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Operating current0 ... 200 mA
No-load supply current≤ 16 mA
Switching state indicatorMultihole-LED, yellow
Functional safety related parameters
MTTFd1560 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Connection typeConnector M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Housing diameter12 mm
Degree of protectionIP67
General information
Scope of delivery2 self locking nuts in scope of delivery

Documents: NBN8-12GM50-E2-V1

Technical informationLanguageFile TypeFile Size
Installation instructions, locking nut / Montageanleitung, Muttern mit SperrverzahnungALLPDF1117 KB

Approvals+Certificates: NBN8-12GM50-E2-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-2578BPDF169 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB

Associated Products: NBN8-12GM50-E2-V1

Accessories

Mounting flange, 12 mmfa

Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.