Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB5-18GM60-A2-V1-3G-3D

NBB5-18GM60-A2-V1-3G-3D
  • 5 mm flush
  • ATEX-approval for zone 2 and zone 22

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB5-18GM60-A2-V1-3G-3D

General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance5 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 4.05 mm
Reduction factor rAl 0.25
Reduction factor rCu 0.15
Reduction factor r304 0.66
Output type4-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 800 Hz
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 20 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1138 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typeConnector plug M12 x 1 , 4-pin
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
Equipment protection level Dc (tc)
Special conditions
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
General information
Use in the hazardous areasee instruction manuals

Documents: NBB5-18GM60-A2-V1-3G-3D

Instruction manualsLanguageFile TypeFile Size
ИнструкцииBULPDF157 KB
Návod k poużitíCZEPDF151 KB
Instruktions manualDANPDF149 KB
Instruction manualENGPDF150 KB
KasutusjuhendESTPDF145 KB
KäyttöohjeFINPDF145 KB
Manuel d'instructionsFRAPDF153 KB
BetriebsanleitungGERPDF151 KB
Οδηγίες χρήσηςGREPDF159 KB
HandleidingHOLPDF149 KB
Instruction manual / BetriebsanleitungHRVPDF149 KB
Használati útmutatóHUNPDF152 KB
Manuale di istruzioniITAPDF149 KB
Lietošanas pamācībaLAVPDF149 KB
Instrukciju vadovasLITPDF150 KB
Instrukcja obsługiPOLPDF153 KB
Manual de instruçõesPORPDF151 KB
Manual de utilizareRONPDF150 KB
Návod na poużitieSLKPDF150 KB
Navodila za uporaboSLVPDF148 KB
Manual de instruccionesSPAPDF151 KB
ManualSWEPDF147 KB
Technical information
Installation conditionsENGPDF1053 KB
EinbaubedingungenGERPDF1054 KB

Approvals+Certificates: NBB5-18GM60-A2-V1-3G-3D

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-1367APDF52 KB
Certificates
Canada USA CSA Ordinary Location1007121PDF99 KB
Canada USA UL Ordinary Location20170306-E87056PDF407 KB
Europe Pepperl+Fuchs ATEX Category 3 D CertificatePF15CERT3774XPDF1001 KB
Europe Pepperl+Fuchs ATEX Category 3 G CertificatePF15CERT3754XPDF1015 KB

Associated Products: NBB5-18GM60-A2-V1-3G-3D

Accessories

Mounting flange, 18 mmfa

Quick mounting bracket with dead stopfa
VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.