Serviceline Industrial Sensors
Serviceline Explosion Protection

Inductive sensor NBB2-F76-E2-0,5M

NBB2-F76-E2-0,5M
  • 2 mm flush
  • 3-wire DC

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  NBB2-F76-E2-0,5M

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Reduction factor rAl 0.25
Reduction factor rCu 0.2
Reduction factor r304 0.63
Reduction factor rBrass 0.31
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 1500 Hz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Operating current0 ... 100 mA
Off-state current0 ... 0.5 mA typ. 10 µA at 25 °C
No-load supply current≤ 15 mA
Switching state indicatorLED yellow
Functional safety related parameters
MTTFd1056 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 0.5 m
Core cross-section3 x 0.09 mm2
Housing materialPC
Degree of protectionIP67
Cable
Cable diameter2.3 mm ± 0.2 mm
Bending radius> 10 x cable diameter
Mass5 g
Tightening torque, fastening screws0.7 Nm

Documents: NBB2-F76-E2-0,5M

DocumentsLanguageFile TypeFile Size
EPLAN macro EMA / EPLAN Makro EMAALLEMA91 KB

Approvals+Certificates: NBB2-F76-E2-0,5M

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-3061APDF169 KB